[Amniotic fluid volume associated with fetal anomalies diagnosed in a reference center in the Brazilian Northeast].

نویسندگان

  • Carlos Noronha Neto
  • Alex Sandro Rolland Souza
  • Olímpio Barbosa Moraes Filho
  • Adriana Mota Bione Noronha
چکیده

PURPOSE to determine factors associated to amniotic fluid volume and frequencies of fetal anomalies, in a reference center in Pernambuco. METHODS a transversal study performed in high-risk pregnant women submitted to obstetrical morphological ultrasound, from March 2002 to March 2006, at an institution from Recife, Pernambuco, Brasil. The intrauterine diagnosis was confirmed after birth. Sociodemographic and obstetrical characteristics, amniotic liquid volume and presence of fetal anomalies were the variables studied. Fisher's exact, chi2, and Student's t tests, at a significance level of 5% were applied to verify the correlation among the variables. Prevalence rate and confidence interval at 95% were calculated. Multiple logistic regression analysis was performed at a significance level of 5%. RESULTS Two hundred and fifty-seven pregnant women (56.2%) with congenital anomalies and 200 (43.8%) without anomalies, confirmed in the postnatal, were included in the study. The average of maternal ages and gestation periods were 24.8+/-6.5 years and 35.9+/-3.7 weeks, respectively. The fetal anomalies were discovered in the central nervous system (50.6%) and genitourinary tract (23.0%). The presence of congenital anomalies were significantly linked with reduced liquid/oligohydramnios (p=0.0002) and increased liquid/polyhydramnios (p<0.0001). Intrauterine mortality was more frequent in the group with anomalies, as compared to the healthy fetuses (10.5 versus 2.5%; p<0.01). CONCLUSIONS The rate of congenital anomalies in the high-risk pregnant women group was 56.2%. Most of the central nervous system malformations were diagnosed intrauterus. Changes in the amniotic fluid were the factors more strongly associated with congenital anomalies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Is uterine height able to diagnose amniotic fluid volume deviations?].

PURPOSE To evaluate the performance of a Brazilian reference curve of fundal height (FH) regarding its capacity of screening the deviations of volume of amniotic fluid using a Brazilian reference curve of amniotic fluid index (AFI) as gold standard. METHODS This was a cross-sectional study evaluating 753 pregnant women receiving prenatal care at the public health services of João Pessoa (PB),...

متن کامل

گزارش یک مورد آمنیوسنتزتراپی در پلی‌هیدرآمنیوس شدید از بیمارستان فیروزگر

    Introduction: Polyhydramniosus is a pathological condition characterized by excessive accumulation of amniotic fluid, usually more than 2100ml. It is associated with numerous fetal anomalies and causes maternal complications due to overdistension of the uterus. An AFI(Amniotic Fluid Index) exceeding 24cm constitutes the diagnosis of severe polyhydramniosus. Case Report: The patient was a 25...

متن کامل

A prospective clinical study of feto-maternal outcome in pregnancies with abnormal liquor volume.

UNLABELLED AIMS AND OBJECTIVE(S): Evaluating feto-maternal outcome in pregnancies with abnormal liquor volume. MATERIAL AND METHOD(S) 200 pregnant subjects between 20 and 42 weeks of gestation, who were clinically suspected to have an abnormal amniotic fluid volume (oligohydramnios or polyhydramnios) were subjected to ultrasonographic (USG) assessment of amniotic fluid index. The subjects wer...

متن کامل

Prenatal Diagnosis of Triploidy in Fetus with Unexpected Chromosomal Translocation of Maternal Origin

Triploidy is a lethal chromosomal abnormality. Foetuses with triploid condition have a tendency to die in early conception and very few survive to term. In this study, we report the prenatal diagnosis of fetal triploidy with unexpected chromosomal translocation. A 27 years old women was referred to our clinical cytogenetic department due to history of previous conceptus with intrauterine growth...

متن کامل

Idiopathic polyhydramnios and postnatal abnormalities.

OBJECTIVE To investigate the proportion and type of fetal anomalies that are associated with polyhydramnios and to examine whether in cases with idiopathic polyhydramnios during the course of pregnancy and fetal anomalies only diagnosed after birth, antenatal characteristics differ. METHODS This was a retrospective study involving all pregnancies with polyhydramnios defined by a deepest pool ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia

دوره 31 4  شماره 

صفحات  -

تاریخ انتشار 2009