Clinical validation and assessment of a modular fluorescent imaging system and algorithm for rapid detection and quantification of dental plaque

نویسندگان

  • Keith Angelino
  • Pratik Shah
  • David A. Edlund
  • Mrinal Mohit
  • Gregory Yauney
چکیده

BACKGROUND Significant numbers of adults and children have untreated plaque due to poor oral hygiene and consequently suffer from associate dental and systemic diseases. METHODS A handheld device equipped with 405 nm light-emitting diodes was constructed to examine the prevalence of red fluorescence signatures associated with dental plaque. This device was used for in vivo imaging of all four incisors and all four canines of twenty-eight consenting human subjects. The same areas were further imaged under white light illumination with a commercial image-processing based plaque-imaging device, and evaluated by a hygienist and dentist. A custom computer vision algorithm using pixel information was developed to calculate plaque coverage ratios ranging from 0 (no plaque) to 1 (complete plaque coverage) for images captured by both devices. RESULTS The algorithm calculated red fluorescence-based plaque coverage ratios ranging from 0.011 to 0.211 for the subjects imaged. Clinical assessment and statistical analyses of associated plaque ratios of the 405 nm device images indicated high sensitivity and specificity in detecting dental plaque by the experimental device compared to the commercial reference device. CONCLUSIONS The low-cost and open source 405 nm device and the associated computer vision algorithm successfully captured red fluorescence signatures associated with dental plaque and demonstrated comparable performance to a commercially available device. Therefore, a proof of concept validation was provided for the construction and application of a sensitive cost-effective plaque-detecting device. A miniaturized mobile adaptable version of the device was also provided, together with and a step-by-step guide for device assembly and webhost the associated software, to facilitate open-source access to a cost-effective at-home, in-clinic oral care technology. TRIAL REGISTRATION ClinicalTrials.gov NCT03379337, December 19 2017. Retrospectively registered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SPIO-Annexin V, a potential probe for MRI detection of radiation induced apoptosis

Background: Finding a suitable method for rapid, accurate and reliable estimation of absorbed dose has high priority in management of the radiation exposed persons. Shortly after radiation exposure, apoptosis is a major detriment in proliferative tissues such as the hematopoietic system. Therefore, quantification of apoptosis in these tissues could be useful for rapid estimation of radiation ex...

متن کامل

Contrast Enhancement of Mammograms for Rapid Detection of Microcalcification Clusters

Introduction Breast cancer is one of the most common types of cancer among women.  Early detection of breast cancer is the key to reducing the associated mortality rate. The presence of microcalcifications clusters (MCCs) is one of the earliest signs of breast cancer. Due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially t...

متن کامل

The Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries

Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a den...

متن کامل

Validation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column

This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...

متن کامل

Validation of an UHPLC-MS/MS method for simultaneous analysis of 11 mycotoxins in wheat flour Using Immunoaffinity column

This study focuses on optimization and validation of an Ultrahigh-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous analysis of 11mycotoxins: Aflatoxin B1, T-2 Toxin, Ochratoxin A, Deoxynivalenol and Zearalenone in wheat matrix. Sample extraction and cleanup procedure is based on a single extraction step using acetonitrile/water/acetic acid mixture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017