Optimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle
نویسندگان
چکیده
Received: 5 April 2004 / Accepted: 14 June 2004 / Published: 15 June 2004 __________________________________________________________________________________ Abstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux ) ( 1 − ∆ ∝ T Q ] is adopted, the fundamental optimal relation between the coefficient of performance (COP) and the cooling load, as well as the maximum cooling load and the corresponding COP of the cycle coupled to constant-temperature heat reservoirs are derived by using finite-time thermodynamics or thermodynamic optimization. The optimal distribution of the heat-transfer surface areas is also obtained. Moreover, the effects of the cycle parameters on the COP and the cooling load of the cycle are studied by detailed numerical examples. The results obtained herein are of importance to the optimal design and performance improvement of an absorption refrigeration cycle.
منابع مشابه
Exergoeconomic performance optimization for a combined cooling, heating and power generation plant with an endoreversible closed Brayton cycle
Finite time exergoeconomic performance of a combined cooling, heating and power generation (CCHP) plant composed of one endoreversible closed Brayton cycle and one endoreversible four-heat-reservoir absorption refrigeration cycle is investigated by using finite time thermodynamics. Heat conductance distribution among hot-, cold-, thermal consumer-, generator-, absorber-, condenserand evaporator...
متن کاملImprovement of simple and regenerative gas turbine using simple and ejector-absorption refrigeration
The exhaust gases of gas turbine power plant carry a significant amount of thermal energy that is usually expelled to the atmosphere this causes a reduction in net work and efficiency of gas turbine. On the other hand, the generated power and efficiency of gas turbine plants depend largely on the temperature of the inlet air, So that they both increase as the inlet air temperature decreases. Th...
متن کاملPerformance evaluation of irreversible cascaded refrigeration and heat pump cycles
This communication presents finite time thermodynamic optimization of irreversible cascaded refrigeration and heat pump cycles having source/sink thermal reservoirs of finite heat capacitance. A general expression for the optimum coefficient of performance of the refrigerator/heat pump is derived at minimum power input and given cooling/heating load conditions, respectively. External irreversib...
متن کاملHierarchical Decomposition Thermodynamic Approach for the Study of Solar Absorption Refrigerator Performance
A thermodynamic approach based on the hierarchical decomposition which is usually used in mechanical structure engineering is proposed. The methodology is applied to an absorption refrigeration cycle. Thus, a thermodynamic analysis of the performances on solar absorption refrigerators is presented. Under the hypothesis of an endoreversible model, the effects of the generator, the solar concentr...
متن کاملThermodynamic Analysis of the Irreversibilities in Solar Absorption Refrigerators
A thermodynamic analysis of the irreversibility on solar absorption refrigerators is presented. Under the hierarchical decomposition and the hypothesis of an endoreversible model, many functional and practical domains are defined. The effect of external heat source temperature on the entropy rate and on the inverse specific cooling load (ISCL) multiplied by the total area of the refrigerator A/...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Entropy
دوره 6 شماره
صفحات -
تاریخ انتشار 2004