Hemodynamic Changes Following Endotracheal Intubation With Glidescope® Video-Laryngoscope in Patients With Untreated Hypertension

نویسندگان

  • Majid Dashti
  • Shahram Amini
  • Rasoul Azarfarin
  • Ziae Totonchi
  • Maryam Hatami
چکیده

BACKGROUND Tracheal intubation can be associated with considerable hemodynamic changes, particularly in patients with uncontrolled hypertension. The GlideScope(®) video-laryngoscope (GVL) is a novel video laryngoscope that does not need direct exposure of the vocal cords, and it can also produce lower hemodynamic changes due to lower degrees of trauma and stimuli to the oropharynx than a Macintosh direct laryngoscope (MDL). OBJECTIVES The aim of this clinical trial was to compare hemodynamic alterations following tracheal intubation with a GVL and MDL in patients with uncontrolled hypertension. PATIENTS AND METHODS Sixty patients who had uncontrolled hypertension and scheduled for elective surgery requiring tracheal intubation, were randomly assigned to receive intubated with either a GVL (n = 30) or a MDL (n = 30). Intubation time, heart rate, rate pressure product (RPP), and mean arterial blood pressure (MAP), were compared between the two groups at; baseline, following induction of anesthesia, after intubation, and at one minute intervals for 5 minutes. RESULTS A total of 59 patients finished the study. Intubation time was longer in the GVL group (9.80 ± 1.27 s) than in the MDL group (8.20 ± 1.17 s) (P < 0.05). MAP, pulse rate, and RPP were lower in the GVL than the MDL group after endotracheal intubation (P < 0.05). MAP, heart rate, and RPP returned to pre-intubation values at 3 and 4 minutes after intubation in the GVL and MDL groups, respectively (P < 0.05). CONCLUSIONS Hemodynamic fluctuations in patients with uncontrolled hypertension after endotracheal intubation were lower with the GVL than the MDL technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope

Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...

متن کامل

Comparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery

Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...

متن کامل

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

Hemodynamic Changes Following Endotracheal Intubation in Patients Undergoing Cesarean Section With General Anesthesia: Application of Glidescope® Videolaryngoscope Versus Direct Laryngoscope

BACKGROUND Endotracheal intubation is usually associated with hemodynamic changes, especially in patients undergoing cesarean section by general anesthesia. GlideScope® videolaryngoscope (GVL) is a novel video laryngoscope, which does not need direct exposure of vocal cords and produces lesser hemodynamic changes due to lower degrees of trauma and stimuli to oropharynx than the Macintosh direct...

متن کامل

Comparing GlideScope Video Laryngoscope and Macintosh Laryngoscope Regarding Hemodynamic Responses During Orotracheal Intubation: A Randomized Controlled Trial

BACKGROUND To determine if the GlideScope® videolaryngoscope (GVL) could attenuate the hemodynamic responses to orotracheal intubation compared with conventional Macintosh laryngoscope. OBJECTIVES The aim of this relatively large randomized trial was to compare the hemodynamic stress responses during laryngoscopy and tracheal intubation using GVL versus MCL amongst healthy adult individuals r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2014