Treatment of obstructive sleep apnea with oral appliances

نویسندگان

  • Andressa Otranto de Britto Teixeira
  • Luciana Baptista Pereira Abi-Ramia
  • Marco Antonio de Oliveira Almeida
چکیده

BACKGROUND The purpose of this study was to evaluate the effectiveness of mandibular advancement devices (MADs) for treatment of obstructive sleep apnea syndrome (OSAS) compared with the results obtained with a placebo device in accordance with the following indicators: apnea hypopnea index (AHI) per hour of sleep, apnea index (AI) per hour of sleep, mean oxyhemoglobin saturation, sleep efficiency, and percentage of rapid eye movement (REM) sleep. METHODS This is a controlled, prospective longitudinal study with a follow-up time of 10.5 months. Nineteen patients (8 females and 11 males) with mean age 48.6 years (SD 9.6) were selected for the study. The sample was randomized in terms of device use, and the evaluation design was double blind. A total of 57 polysomnography tests were studied (at baseline, after the use of a MAD, and after the use of placebo). The following variables were assessed: AHI, AI, mean oxyhemoglobin saturation, percentage of REM sleep, and sleep efficiency. Wilcoxon and Mann-Whitney tests were used for evaluating data (p<0.05). RESULTS Reductions from 16.3 to 11.7 in AHI and from 5.7 to 3.8 in AI were observed after MAD use. During the use of placebo, AHI increased from 16.3 to 19.6, and AI from 5.7 to 7.5. The other indexes showed no statistically significant differences. CONCLUSIONS Treatment with oral appliances, i.e., MADs, can be an effective alternative for mild and medium-to-moderate OSAS, but requires strict monitoring due to differences in individual response to this therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of obstructive sleep apnea patients using oral appliances--our experiences.

BACKGROUND/AIM Obstructive sleep apnea (OSA) is one of the most prevalent sleep disorders. It is recognized as a serious risk factor for car and workplace accidents due to daytime sleepiness, and factor for coronary heart diseases and stroke. The aim of this study was to examine the effectiveness of oral appliances for mandibular advance in treating mild to moderate OSA. METHODS A total of 15...

متن کامل

Efficacy versus Effectiveness in the Treatment of Obstructive Sleep Apnea: CPAP and Oral Appliances

Obstructive sleep apnea (OSA) is a chronic disorder and effective long-term treatment is necessary to prevent associated health risks. Standard treatment remains continuous positive airway pressure which is highly efficacious but has well-recognized limitations, with suboptimal patient acceptance and adherence rates, which in turn obviates the desired health benefits. The leading alternative de...

متن کامل

Oral appliances for the treatment of snoring and obstructive sleep apnea.

Oral appliances have been used by dentists for several decades to treat snoring and obstructive sleep apnea. Although these devices are regulated by the Food and Drug Administration, most have undergone only sparse clinical testing for efficacy and safety. Most otolaryngologists are not well-versed in their applicability as treatment options. This review summarizes the historical development of...

متن کامل

Obstructive Sleep Apnea, Prevalence, Etiology & Role of Dentist & Oral Appliances in Treatment: Review Article

Objective: The aim of this article is to provide a detailed description for obstructive sleep apnea regarding its signs and symptoms, the way it is diagnosed, the risk factors, management, the role of dentists and oral appliances in treatment and consequences of untreated condition. Material and Method: Electronic searching was done in PubMed, Medline, EMBASE and CENTRAL databases. Inclusion cr...

متن کامل

Titratable oral appliances for the treatment of snoring and obstructive sleep apnea.

The American Sleep Disorders Association recommends that oral appliances (OAs) be used in patients with primary snoring or mild obstructive sleep apnea (OSA) and in patients with moderate to severe OSA1,2 who are intolerant of or refuse treatment with nasal continuous positive airway pressure (nCPAP). Because of the life-threatening implications of a number of sleep disorders, it is imperative ...

متن کامل

Snoring and Obstructive Sleep Apnea (osa) Are Caused in Part by Repetitive Dynamic Obstruc- Tion of the Oropharyngeal

SNORING AND OBSTRUCTIVE SLEEP APNEA (OSA) ARE CAUSED IN PART BY REPETITIVE DYNAMIC OBSTRUCTION OF THE OROPHARYNGEAL AIRWAY. There is growing epidemiological and experimental evidence that OSA, and to a lesser degree snoring, are associated with a wide variety of adverse health outcomes.1, 2 OSA is considered one of several potentially treatable contributors to systemic hypertension, and has bee...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013