Design of Pulse Oximeter with WiFi connectivity and interoperability with standard HL7 and IEEE 11073-10404:2008
نویسنده
چکیده
Given that health is so relevant for global productivity and competitiveness, and that the ICTs play an important role in all of the productivity factors, this work makes use of the ICTs in health matters proposing the to use a WiFi oximeter. This article describes the operating principles of a Pulse Oximeter (PO) which is an opto-electronic non-invasive medical instrument capable of measuring changes in HR and SpO2 at the fingertip and its upgrade to the standards; HL7 and IEEE 11073-10404:2008, its design, and its validation against the three existing devices. Variables (SpO2%, Ppm, Temperature) were compared, and its performance and impact were discussed the addition of the WiFi technology allows a better comunication between devices, causing a greate impact in global competiveness.
منابع مشابه
Design of Pulse Oximeter with WiFi connectivity and interoperability with standard HL7 and IEEE 11073-10404:2008 (extended version)
Given that health is so relevant for global productivity and competitiveness, and that the Information and Communications Technology (ICTs) play an important role in all of the productivity factors, this work makes use of the ICTs in health matters proposing the to use a WiFi oximeter. This article describes the operating principles of a Pulse Oximeter (PO) which is an opto-electronic non-invas...
متن کاملComparison and Analysis of ISO/IEEE 11073, IHE PCD-01, and HL7 FHIR Messages for Personal Health Devices
Objectives Increasing use of medical devices outside of healthcare facilities inevitably requires connectivity and interoperability between medical devices and healthcare information systems. To this end, standards have been developed and used to provide interoperability between personal health devices (PHDs) and external systems. ISO/IEEE 11073 standards and IHE PCD-01 standard messages have b...
متن کاملInteroperability of Medical Device Information and the Clinical Applications: An HL7 RMIM based on IEEE 11073 DIM
Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if the clinical applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from...
متن کاملA Three-Wavelength Pulse Oximeter for Carboxyhemoglobin Determination
Pulse oximetry measures the relative concentration of arterial oxygenated hemoglobin and reduced hemoglobin. This paper presents the design of a pulse oximeter, which measures the presence of a third substance, carboxyhemoglobin (HbCO), by unfiltered LEDs at 660 nm, 810 nm, and 940 nm. Background information is given on the theory of pulse oximetry. Theoretical approximations and calculations w...
متن کاملInteroperable End-to-End Remote Patient Monitoring Platform based on IEEE 11073 PHD and ZigBee Health Care Profile.
This paper describes the implementation of an end-to-end remote monitoring platform based on the IEEE 11073 standards for Personal Health Devices (PHD). It provides an overview of the concepts and approaches and describes how the standard has been optimized for small devices with limited resources of processor, memory and power and that use short range wireless technology. It explains aspects o...
متن کامل