The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) assay was used and haematoxylin and eosin staining was performed to evaluate morphological changes. Copper wire served as the control to determine the morphology of severe toxicity, and native cell cultures and silk were used as the negative controls. Morphological evaluation of the native cell cultures revealed no toxic reactions. The ranking, from mild to severe toxicity was as follows: stainless steel < Nitinol = TMA. There were no significant differences between TMA and Nitinol. The MTT assay revealed the following mean percentage values for viability: native cell line (negative control), 100; stainless steel, 102.25; TMA, 87.4; Nitinol, 85.3; and copper wire (positive control) 57.2. Histological evaluation of the 3D cell cultures showed no severe toxicity or loss of viability for any of the wires. However, relative comparison between the different wires revealed that stainless steel induced less toxicity/loss of viability compared with TMA and Nitinol wire.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Galvanic Corrosion among Different Combination of Orthodontic Archwires and Stainless Steel Brackets

Introduction: The aim of this study was to assess the galvanic behavior of different bracket and archwire combinations that are commonly used in orthodontic treatments. Methods: Three types of orthodontic archwires with a diameter of 0.016×0.022 inch and 80 standard edgewise maxillary central incisor brackets were selected. Three groups consisted of different wire-bracket couples and one group ...

متن کامل

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

Abstract of the PhD thesis:

of the PhD thesis: Influence of archwires mechanical properties and surface caracteristics in orthodontic biomechanics Coordinator: Mariana PACURAR,Prof. M.D. PhD student: Silvia-Izabella POP The principle of fixed orthodontic therapy is based on tooth movement, generated by light and continous forces. Orthodontic archwires are key elements in producing such forces and their clinical selection ...

متن کامل

Contemporary Esthetic Orthodontic Archwires – A Review

Growing demand of invisible braces byesthetically conscious patients has led to remarkable inventions in materials for esthetic labial archwires. Archwires with excellent optical clarity and mechanical properties comparable to conventional archwires have been manufactured by almost all the leading companies of orthodontic products in the past two decades, but their clinical use is still limited...

متن کامل

Effect of Fluoride on Nickel-Titanium and Stainless Steel Orthodontic Archwires: An In-Vitro Study

OBJECTIVES The commonly used Nickel-Titanium (NiTi) archwires in orthodontic treatment are often exposed to fluoride-containing mouthwashes. The aim of this in-vitro study was to evaluate and compare the corrosion resistance of three commercially available NiTi archwires exposed to 0.05 wt% and 0.2 wt% fluoride mouthwashes. MATERIALS AND METHODS Three different types of NiTi archwires, 0.016″...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2006