An Experimental Study of Transvenous Defibrillation Using a Coronary Sinus Catheter

نویسنده

  • ALAN H. KADISH
چکیده

KADISH, A.H., ET AL.: An Experimental Study of Transvenous Defibrillation Using a Coronary Sinus Catheter. The efficacy of a transvenous defibrillating system, utilizing bipolar right ventricular and coronary sinus catheters was evaluated in 14 normal mongrel'dogs. Tivo groups of seven animals each were studied^ During all shocks, the right ventricular apex electrode sensed as the anode. In both groups, defihrillation was performed using the proximal pole of the right veritricular catheter (superior vena cava), as the cathode served as a control (configuration A). In group 1, a coronanj sinus cathode (configuration B) was compyared to control. The mean energy at which 50% or more of the shocks were successful was similar for configuration B (20.7 ± 7.9 joules) and for configuration A (18.8 ± 9.4 joules). In group 2, the superior vena cava and coronary sinus electrodes served as a common cathode (configuration C). Mean defibrillation energy at which 50% or more of the shocks loas successful was 21.4 ± 9.0 joules for configuration C and 27.1 ± 9.5 joules for configuration A (P < 0.01). Leading edge voltage was similar for all three configurations, but shock duration was longer for configuration A (11.3 ± 2.8 msec) than configuration B (6.6 ± 1.8 msec) or C(6.1 ± 1.5; P < 0.05). Nonsustained ventricular tachycardia and transient heart block were common, but no damage to the coronary sinus ivas noted despite the delivery of up to 38 shocks. Conclusions: (V mth the catheter system used] coronary sinus to right ventricular apex defibrillation system offered no advantages over a superior vena cava to right ventricular apex system; (2) A three-electrode system zoith the high right atrium and coronary sinus serving as the common cathode reduced defibrillation thresholds significantly without any severe short-term adverse consequences; and (3) Improvements in catheter design may make a coronary sinus catheter part of a feasible transvenous defibrillating system. (J Electrophysiol 3:253-260, 1989)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous defibrillation in humans via the coronary sinus.

A consistently effective transvenous defibrillation system for use in automatic defibrillators could significantly alter the approach to patients at risk of sudden death. Transvenous defibrillation systems that use a right ventricular (RV) electrode only or an RV electrode in combination with a chest patch are relatively inefficient at applying current to the posterolateral left ventricle. An R...

متن کامل

Atrial defibrillation with a transvenous lead: a randomized comparison of active can shocking pathways.

OBJECTIVES The purpose of this study was to compare transvenous atrial defibrillation thresholds with lead configurations consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Low atrial defibrillation thresholds are achieved using complex lead systems including coils in the coronary sinus. However, the efficacy of more simple ventricular defi...

متن کامل

A Prospective, Randomized Study

Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...

متن کامل

A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.

A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...

متن کامل

Transvenous biventricular defibrillation halves energy requirements in patients.

BACKGROUND Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation req...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005