Objective assessment of crystalline lens opacity level by measuring ocular light scattering with a double-pass system.

نویسندگان

  • Florence Cabot
  • Alain Saad
  • Colm McAlinden
  • Nour Maya Haddad
  • Alice Grise-Dulac
  • Damien Gatinel
چکیده

PURPOSE To assess the crystalline lens opacity level by measuring ocular light scattering with a double-pass system. DESIGN Prospective, single-center, cross-sectional study. METHODS Two hundred fifty-three eyes of 135 patients referred for cataract evaluation were enrolled. Patients with corneal or retinal anomalies potentially impairing ocular transparency were excluded. Lens opacification was assessed by the Lens opacities classification system III. Optical Quality Analysis System (Visiometrics SL) measurements provided ocular Modulation Transfer Function cutoff frequency and Objective Scatter Index. Best-corrected visual acuity and Quality of Vision questionnaire scores (Rasch-scaled) were recorded. We analyzed correlations between visual acuity, type and severity of cataract, Optical Quality Analysis System measurements, and discomfort level in each group. RESULTS In patients with best-corrected visual acuity better than 20/32, we found correlations between Objective Scatter Index, Modulation Transfer Function, and visual acuity (r = 0.4, P < .0001). The Objective Scatter Index, Modulation Transfer Function, and visual acuity were correlated with each type of cataract. In patients with good visual acuity and moderate functional symptoms, the Objective Scatter Index values also were correlated to the severity of posterior subcapsular cataract (r = 0.4, P = .0006). CONCLUSIONS Patients with incipient cataract may report visual discomfort, despite minor lens opacity on slit-lamp examination, minor loss of best-corrected visual acuity, or both. The measurement of ocular scattering with the Optical Quality Analysis System device may be a useful tool in the preoperative evaluation of patients with early cataract.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cause of monocular diplopia diagnosed by combining double-pass retinal image assessment and Hartmann-Shack aberrometry.

PURPOSE To report an advanced optical procedure developed for the diagnosis of a particular case of diplopia. METHODS This approach combined the quantification of the level of intraocular scattering by using an Objective Scatter Index provided by a double-pass instrument (Optical Quality Analysis System) with the analysis of higher order aberrations using a Hartmann-Shack wavefront sensor. ...

متن کامل

DISLOCATIONS STRUCTURE AND SCATTERING PHENOMENON IN CRYSTALLINE CELL SIZE OF 2024 AL ALLOY DEFORMED BY ONE PASS OF ECAP AT ROOM TEMPERATURE

Variation in microstructural features of 2024 aluminum alloy plastically deformed by equal channel angular pressing (ECAP) at room temperature, was investigated by X-Ray diffraction in this work. These include dislocation density dislocation characteristic and the cell size of crystalline domains. Dislocations contrast factor was calculated using elastic constants of the alloy such as C 11, C 2...

متن کامل

Binocular open-view system to perform estimations of aberrations and scattering in the human eye.

We present a system that integrates a double-pass (DP) instrument and a Hartmann-Shack (HS) wavefront sensor to provide information not only on aberrations, but also on the scattering that occurs in the human eye. A binocular open-view design permits evaluations to be made under normal viewing conditions. Furthermore, the system is able to compensate for both the spherical and astigmatic refrac...

متن کامل

An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts

PURPOSE To propose a new objective scatter index (OSI) based in the analysis of double-pass images of a point source to rank and classify cataract patients. This classification scheme is compared with a current subjective system. METHODS We selected a population including a group of normal young eyes as control and patients diagnosed with cataract (grades NO2, NO3 and NO4) according to the Le...

متن کامل

Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes

PURPOSE We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND METHODS Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 155 4  شماره 

صفحات  -

تاریخ انتشار 2013