How Reliable Are ATP Bioluminescence Meters in Assessing Decontamination of Environmental Surfaces in Healthcare Settings?

نویسندگان

  • Navid Omidbakhsh
  • Faraz Ahmadpour
  • Nicole Kenny
چکیده

BACKGROUND Meters based on adenosine triphosphate (ATP) bioluminescence measurements in relative light units (RLU) are often used to rapidly assess the level of cleanliness of environmental surfaces in healthcare and other settings. Can such ATP measurements be adversely affected by factors such as soil and cleaner-disinfectant chemistry? OBJECTIVE This study tested a number of leading ATP meters for their sensitivity, linearity of the measurements, correlation of the readings to the actual microbial contamination, and the potential disinfectant chemicals' interference in their readings. METHODS First, solutions of pure ATP in various concentrations were used to construct a standard curve and determine linearity and sensitivity. Serial dilutions of a broth culture of Staphylococcus aureus, as a representative nosocomial pathogen, were then used to determine if a given meter's ATP readings correlated with the actual CFUs. Next, various types of disinfectant chemistries were tested for their potential to interfere with the standard ATP readings. RESULTS All four ATP meters tested herein demonstrated acceptable linearity and repeatability in their readings. However, there were significant differences in their sensitivity to detect the levels of viable microorganisms on experimentally contaminated surfaces. Further, most disinfectant chemistries tested here quenched the ATP readings variably in different ATP meters evaluated. CONCLUSIONS Apart from their limited sensitivity in detecting low levels of microbial contamination, the ATP meters tested were also prone to interference by different disinfectant chemistries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The uses and abuses of rapid bioluminescence-based ATP assays.

Bioluminescence-based ATP testing of solid surfaces has become well established in the food processing industry as part of general hazard analysis and critical control points (HACCP) measures. The rise in healthcare associated infections (HAIs) at the turn of the century focussed attention on the environment as a potential reservoir of the agents responsible for such infections. In response to ...

متن کامل

An Adenosine Triphosphate Bioluminescence Method for Evaluating the Microbial Contamination of the Salad-Preparing Tables and Salad-Serving Dishes in Restaurants of Mashhad City, Iran

Introduction: Consumption of vegetable products is increasing commonly in the world because they are recognized as an important source of nutrients, vitamins, and fiber for humans. Salads are among the most widely used foods that are also known as the most contaminated foods in restaurants. This study was conducted to determine the microbial contamination of salad-preparing tables and salad-ser...

متن کامل

Removing bacteria from hospital surfaces: a laboratory comparison of ultramicrofibre and standard cloths.

We compared the ability of ultramicrofibre-woven cloths with conventional cloths moistened with water only, for their ability to remove several types of organisms relevant to hospital-acquired infections from a variety of surfaces in hospitals. We showed that ultramicrofibre cloths consistently outperformed conventional cloths in their decontamination ability, across all surfaces, and irrespect...

متن کامل

Assessing the efficiency of floor disinfection on bacterial decontamination in sanandaj governmental hospitals

Despite regular disinfection and decontamination of the hospital floors and surfaces, resistant pathogens from the hospital surfaces and their transmission to humans have been reported recently. The resistance of pathogens to the disinfectant agents or failed disinfection techniques have put the routine floor and non-critical surface disinfection done in hospitals into question with regard to t...

متن کامل

Cleaning and decontamination efficacy of wiping cloths and silver dihydrogen citrate on food contact surfaces.

AIMS   To test the efficacy of four wipe cloth types (cotton bar towel, nonwoven, microfibre and blended cellulose/cotton) with either quaternary ammonia cleaning solution or silver dihydrogen citrate (SDC) in cleaning food contact surfaces. METHODS   Swab samples collected from untreated, cloth-treated and cloth disinfectant-treated surfaces were subjected to hygiene monitoring using adenosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014