Pd-porphyrin-cross-linked implantable hydrogels with oxygen-responsive phosphorescence.

نویسندگان

  • Haoyuan Huang
  • Wentao Song
  • Guanying Chen
  • Justin M Reynard
  • Tymish Y Ohulchanskyy
  • Paras N Prasad
  • Frank V Bright
  • Jonathan F Lovell
چکیده

Development of long-term implantable luminescent biosensors for subcutaneous oxygen has proved challenging due to difficulties in immobilizing a biocompatible matrix that prevents sensor aggregation yet maintains sufficient concentration for transdermal optical detection. Here, Pd-porphyrins can be used as PEG cross-linkers to generate a polyamide hydrogel with extreme porphyrin density (≈5 × 10(-3) m). Dye aggregation is avoided due to the spatially constraining 3D mesh formed by the porphyrins themselves. The hydrogel exhibits oxygen-responsive phosphorescence and can be stably implanted subcutaneously in mice for weeks without degradation, bleaching, or host rejection. To further facilitate oxygen detection using steady-state techniques, an oxygen-non-responsive companion hydrogel is developed by blending copper and free base porphyrins to yield intensity-matched luminescence for ratiometric detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements.

This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined selection of the excitation volume due to the nonlinear two-photon effect. By using a focused laser bea...

متن کامل

Calibration of Pd-porphyrin phosphorescence for oxygen concentration measurements in vivo.

Quantitative measurement of oxygen concentrations in the microvasculature is of prime importance in issues related to oxygen transport to tissue. The introduction of the quenching of the Pd-porphyrin phosphorescence as oxygen sensor in vivo by Wilson et al. (J. Appl. Physiol. 74: 580-589, 1993) has provided in this context a major advance in this area of research. For in vivo application, the d...

متن کامل

Innovative Methodology Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements

Mik, Egbert G., Ton G. van Leeuwen, Nicolaas J. Raat, and Can Ince. Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements. J Appl Physiol 97: 1962–1969, 2004. First published July 9, 2004; doi:10.1152/japplphysiol.01399.2003.—This study describes the use of two-photon excitation phosphorescence lifetime measure...

متن کامل

Light-induced retinal vascular damage by Pd-porphyrin luminescent oxygen probes.

PURPOSE The phosphorescence lifetime of certain metalloporphyrins dissolved in a physiological medium provides an optical signature for local oxygen concentration (pO(2)). This effect is used for measuring physiological pO(2) levels in various tissues. However, the phosphorescence quenching of certain metalloporphyrin triplet states by oxygen also creates singlet oxygen, which is highly reactiv...

متن کامل

Photon energy upconversion in porphyrins: one-photon hot-band absorption versus two-photon absorption

We study the porphyrin S1 ! S0 fluorescence and the photosensitized singlet oxygen Dg ! Rg phosphorescence, both originating from absorption of photons with energy less than the porphyrin S0 ! S1 transition energy. By measuring the excitation intensity dependence of fluorescence at lowered sample temperatures, we are able to discriminate between two parallel processes of one-photon hot-band abs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Advanced healthcare materials

دوره 3 6  شماره 

صفحات  -

تاریخ انتشار 2014