Effect of Osteonecrosis Intervention Rod Versus Core Decompression Using Multiple Small Drill Holes on Early Stages of Necrosis of the Femoral Head: A Prospective Study on a Series of 60 Patients with a Minimum 1-Year-Follow-Up
نویسندگان
چکیده
INTRODUCTION The conventional CD used 10 mm drill holes associated with a lack of structural support. Thus, alternative methods such as a tantalum implant, small drill holes, and biological treatment were developed to prevent deterioration of the joint. The treatment of CD by multiple 3.2 mm drill holes could reduce the femoral neck fracture and partial weight bearing was allowed. This study was aimed to evaluate the effect of osteonecrosis intervention rod versus core decompression using multiple small drill holes on early stages of necrosis of the femoral head. METHOD From January 2011 to January 2012, 60 patients undergoing surgery for osteonecrosis with core decompression were randomly assigned into 2 groups based on the type of core decompression used: (1) a total of 30 osteonecrosis patients (with 16 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with a porous tantalum rod insertion. The diameter of the drill hole for the intervention rod was 10mm.(2) a total of 30 osteonecrosis patients (with 14 hips on Steinburg stageⅠ,20 hips on Steinburg stageⅡ) were treated with core decompression using five drill holes on the lateral femur, the diameter of the hole was 3.2 mm. The average age of the patient was 32.6 years (20-45 years) and the average time of follow-up was 25.6 months (12- 28 months) in the rod implanted group. The average age of the patient was 35.2 years (22- 43 years) and the average time of follow-up was 26.3 months (12-28 months) in the small drill holes group. RESULTS The average of surgical time was 40 min, and the mean volume of blood loss was 30 ml in both surgical groups. The average of Harris score was improved from 56.2 ± 7.1 preoperative to 80.2 ± 11.4 at the last follow-up in the rod implanted group (p < 0.05). The mean Harris score was improved from 53.8 ± 6.6 preoperative to 79.7 ± 13.2 at the last follow-up in the small drill holes group (p<0. 05). No significant difference was observed in Harris score between the two groups. At the last follow-up, 28 of 36 hips were at the same radiographic stages as pre-operation, and 8 deteriorated in the rod implanted group. 26 of 34 hips were at the same radiographic stage as pre-operation, and 8 deteriorated in the small drill holes group. No significant difference was observed in radiographic stage between the two groups. There was no favourable result on the outcome of a tantalum intervention implant compared to multiple small drill holes. DISCUSSION CD via multiple small drill holes would allow similar postoperative load-bearing and seems to result in similar or even better clinical outcome without the prolonged implantation of an expensive tantalum implant. A tantalum rod intervention and core decompression using multiple small drill holes were effective on the stage I hips rather than stage II hips.
منابع مشابه
Treatment of Femoral Head Osteonecrosis (Stages 2B, 3 Ficat) Through Open Direct Core Decompression by Allograft Impaction and Light Bulb Technique
Background: Femoral head avascular necrosis is the cause of paralyzing status of youth population. Initial diagnosisis the main element in treating the disease. Bone grafting and core decompression are the approved cures at the earlysteps of the disease. Hip replacement in a total manner is the common cure in the final stages. The optimal treatment inthe intermediate stages is...
متن کاملComparison of Total Hip Arthroplasty and Core Decompression in Avascular Necrosis of the Femoral Head after Taking Temgesic and Norgesic
Background: Osteonecrosis is common after taking Temgesic and Norgesic. This study intended to suggest the preferable surgical treatment in osteonecrosis patients who use these drugs. Methods: Twenty tree patients with hip osteonecrosis who were hospitalized in the Kerman hospitals after using Temgesic and Norgesic were followed for about 14 months from 2008 to 2010 (from a minimum of 2 months ...
متن کاملAutologous bone marrow cell implantation in the treatment of non-traumatic osteonecrosis of the femoral head: Five year follow-up of a prospective controlled study.
OBJECTIVE To determine the efficacy of bone marrow cell implantation into the necrotic lesion of the femoral head on clinical symptoms and the progression of osteonecrosis of the femoral head in comparison with core decompression. METHODS We studied nineteen patients and twenty four hips with early stage osteonecrosis of the femoral head. The hips were allocated to either core decompression o...
متن کاملSubchondral Insufficiency Fracture of the Femoral Head Treated with Core Decompression and Bone Void Filler Support
Subchondral insufficiency fracture of the femoral head (SIFFH) is characterized by acute onset hip pain without overt trauma. It appears as a low intensity band with bone marrow edema on T1-weighted MRI. The most common course of treatment is protected weight bearing for a period of several weeks. Total hip arthroplasty (THA) has been commonly used if the patient does not respond to the initial...
متن کاملSilent osteonecrosis of the femoral head following high-dose corticosteroid (CS) medications
Background: Osteonecrosis (ON) is known to be one of the most disabling complications following corticosteroid (CS) medications. However, evidence regarding risk of asymptomatic prevalence of ON among different diseases and the impact of variable steroid regimens are conflicting. We aimed to determine the prevalence of ON of femoral head in asymptomatic patients with systemic rheumatic diseas...
متن کامل