Determination of bisphenol-A in water by semi-micro column high-performance liquid chromatography using 2-methoxy-4-(2-phthalimidinyl)phenylsulfonyl chloride as a fluorescent labeling reagent.
نویسندگان
چکیده
A highly sensitive method for the determination of bisphenol-A in water with semi-micro column high-performance liquid chromatography using 2-methoxy-4-(2-phthalimidinyl)phenylsulfonyl chloride as a fluorescent labeling reagent has been developed. The labeling reaction was carried out at 70 degrees C for 20 min in borate buffer (pH 9.5). The derivative eluted at 11.6 min on a reversed-phase column with methanol-water (78:22, v/v) at a flow-rate of 0.2 ml/min. The fluorescence was monitored at 308 nm for excitation and 410 nm for emission. The detection limit (S/N = 3) was 10 fmol per injection. The labeling yield was about 95%.
منابع مشابه
[Development of highly sensitive determination of biogenic compounds by high-performance liquid chromatography with pre-column fluorescence derivatization].
A sensitive fluorescent labeling reagent, 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chloride (DMS-Cl), for the determination of amino compounds in HPLC was developed. DMS-Cl reacted with amino compounds in the basic medium to produce the corresponding fluorescent sulfonamides (excition 318 nm, emission 406 nm in aqueous acetonitrile). When amino acids were analyzed using revers...
متن کاملDetermination of bisphenol A in human breast milk by HPLC with column-switching and fluorescence detection.
A highly sensitive HPLC method was developed for the determination of xenoestrogenic compound, bisphenol A (BPA) in human breast milk samples. After a two-step liquid-liquid extraction, BPA was derivatized with fluorescent labeling reagent, 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl). The excess fluorescent reagent could be removed effectively using a column-switching system. The...
متن کاملImprovement of detection sensitivity of T-2 and HT-2 toxins using different fluorescent labeling reagents by high-performance liquid chromatography.
T-2 and HT-2 toxins are Fusarium mycotoxins that can occur in cereals and cereal-based products. Three fluorescent labeling reagents, i.e. 1-naphthoyl chloride (1-NC), 2-naphthoyl chloride (2-NC) and pyrene-1-carbonyl cyanide (PCC), were used for the determination of T-2 and HT-2 toxins by high-performance liquid chromatography (HPLC) with fluorescence detection (FD). Pre-column derivatization ...
متن کاملSimultaneous determination of phenolic xenoestrogens by solid-phase extraction and high-performance liquid chromatography with fluorescence detection.
A highly sensitive and selective method for simultaneous determination of some hydroxyl group-containing endocrine disruptors, including bisphenol A (BPA), bisphenol B (BPB), bisphenol E (BPE), bisphenol F (BPF) and 4-nonylphenol (4-NP), was developed. The method consists of precolumn derivatization of the analytes, solid-phase extraction (SPE) and subsequent chromatographic analysis by high-pe...
متن کاملA simple and highly sensitive HPLC method with fluorescent detection for determination of pipecolic acid in mouse brain areas.
A simple and highly sensitive high-performance liquid chromatography method for the determination of pipecolic acid in mouse brain areas was developed. After homogenization of brain and pretreatment with o-phthalaldehyde, the pipecolic acid and (2S,3S)-3-methylpyrrolidine-2-carboxylic acid (internal standard) were derivatized with 4-(5,6-dimethoxy-2-phthalimidinyl)-2-methoxyphenylsulfonyl chlor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2005