Fast Deblurring Method for Computed Tomography Medical Images Using a Novel Kernels Set
نویسندگان
چکیده
Medical images such as computed tomography (CT) are degraded by different types of blur due to the imperfect resolution of the imaging system, data loss at the acquisition time and other technical reasons. The fastest way to deblur an image is by convolving a special kernel to the corrupted image. Laplacian kernels are famous and widely used in this field, but the issue is only few kernels are presented. This paper is trying to simulate the blur problem using various types of blur and attempt to restore the degraded images by using twenty novel kernels. Moreover, these kernels were tested with five types of blur that are: Average, Box, Gaussian, Pillbox and Atmospheric turbulence blur to determine which type of blur is suitable to be employed with kernels the most. The accuracy of the experimental results is measured with five diverse methods along with the success and the failure ratios. Finally, these kernels are applied to naturally degraded images obtained from different CT imaging systems.
منابع مشابه
Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملReducing the Gaussian Blur Artifact from Ct Medical Images by Employing a Combination of Sharpening Filters and Iterative Deblurring Algorithms
Obtained images through imaging systems are considered as degraded versions of the original view. Computed Tomography (CT) images have different types of degradations such as noise, blur and contrast imperfections. This paper handles the issue of deblurring CT medical images affected by Gaussian blur. Image deblurring is the procedure of decreasing the blur amount and grant the filtered image w...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کامل