Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

نویسندگان

  • Jie Li
  • Hong Xiao
  • Qingan Zhu
  • Yue Zhou
  • Changqing Li
  • Huan Liu
  • Zhiping Huang
  • Jin Shang
چکیده

PURPOSE This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. METHODS Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of ± 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR. RESULTS All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs. CONCLUSIONS The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...

متن کامل

Unilateral versus bilateral pedicle screw fixation of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF): a meta-analysis of randomized controlled trials

BACKGROUND A few studies focused on unilateral or bilateral pedicle screw (PS) fixation of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) to treat lumbar degenerative diseases have been published. There is still debate over whether one method is superior to another. A systematic review and meta-analysis of randomized controlled trials (RCT) was performed to compare the eff...

متن کامل

Minimally Invasive Transforaminal Lumbar Interbody Fusion with Unilateral Pedicle Screw Fixation: Comparison between Primary and Revision Surgery

Minimally invasive surgery with a transforaminal lumbar interbody fusion (MIS TLIF) is an important minimally invasive fusion technique for the lumbar spine. Lumbar spine reoperation is challenging and is thought to have greater complication risks. The purpose of this study was to compare MIS TLIF with unilateral screw fixation perioperative results between primary and revision surgeries. This ...

متن کامل

Minimally Invasive Unilateral vs. Bilateral Pedicle Screw Fixation and Lumbar Interbody Fusion in Treatment of Multi-Segment Lumbar Degenerative Disorders

BACKGROUND The choice for instrumentation with minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) in treatment of degenerative lumbar disorders (DLD) remains controversial. The goal of this study was to investigate clinical outcomes in consecutive patients with multi-segment DLD treated with unilateral pedicle screw (UPS) vs. bilateral pedicle screw (BPS) instrumented TLIF. MA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015