Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty.

نویسندگان

  • Denis Nam
  • Christopher K Kepler
  • Shane J Nho
  • Edward V Craig
  • Russell F Warren
  • Timothy M Wright
چکیده

HYPOTHESIS Analyses of polyethylene components retrieved at revision of total knee, hip, and shoulder replacements have been used to study the effect of design, patient, and surgical factors on initial implant performance, but no studies have reported similar types of findings in retrieved humeral polyethylene components in reverse total shoulder arthroplasty. Our hypothesis is that while the conforming surface of the humeral polyethylene may predispose it to surface wear modalities, as seen in total hip arthroplasty, the presence of clinical instability may also increase the occurrence of focal contact stresses leading to subsurface fatigue failure. MATERIALS AND METHODS Fourteen humeral polyethylene components were retrieved from revision surgery at a single institution. Each polyethylene was analyzed for 9 modes of damage in each of 4 quadrants into which the bearing surface was divided. For each implant, the most recent radiographs before removal were scored using an adapted radiolucency score, and glenosphere positioning was measured. RESULTS Despite the short mean length of implantation (0.46 ± 0.5 years), scratching and abrasion were seen in 14 and 13 components, respectively, followed by third-body debris and pitting. The modes of damage observed were most severe in the inferior quadrant of the humeral polyethylene. Scapular notching, glenoid, and humeral radiolucencies were prevalent on preoperative radiographs, but their long-term significance has not yet been elucidated. Increased glenosphere inclination was associated with decreased superior and total glenoid radiolucency, along with total polyethylene wear scores. DISCUSSION Promising early, functional results with the use of reverse total shoulder arthroplasty has led to the increased expansion of its use, but high complication and revision rates continue to raise concerns regarding implant longevity. The presence of a clinical, adduction deficit may predispose patients to inferior quadrant polyethylene wear. CONCLUSIONS Impingement of the humeral polyethylene at the lateral edge of the scapula leads to inferior quadrant wear and associated polyethylene failure, and implant instability may predispose the components to fatigue wear mechanisms. Analysis of retrieved humeral polyethylene components, along with patient, design, and surgical factors, provide important information on the causes of component failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Observations on retrieved glenoid components from total shoulder arthroplasty.

HYPOTHESIS Polyethylene components retrieved at revision of total knee and hip replacements have been analyzed to study the effect of design, patient, and surgical factors on initial implant performance, but few studies have reported similar types of findings in retrieved glenoids. MATERIALS AND METHODS From 1979 to 2006, 78 glenoid components were retrieved from revision surgery in 73 patien...

متن کامل

Humeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty

Background: We sought to characterize humeral-sided radiographic changes at a minimum of 2 years after reverseshoulder arthroplasty (RSA) to determine their association with specific implantation techniques.Methods: The immediate and most recent postoperative anteroposterior radiographs of 120 shoulders with primary RSAand a minimum of 2-years of radiographic follow-up were an...

متن کامل

Total Shoulder Arthroplasty

Shoulder arthroplasty has been the subject of marked advances over the last few years. Modern implants provide a wide range of options, including resurfacing of the humeral head, anatomic hemiarthroplasty, total shoulder arthroplasty, reverse shoulder arthroplasty and trauma-specific implants for fractures and nonunions. Most humeral components achieve successful long-term fixation without bone...

متن کامل

Conversion of total shoulder arthroplasty to reverse shoulder arthroplasty made possible by custom humeral adapter.

Reverse shoulder arthroplasty (RSA) is increasingly being used to revise anatomical total shoulder arthroplasty cases. This procedure's high complication rate has been reduced by the availability of modular shoulder systems, which allows the humeral component to be preserved during the conversion. This case report describes the revision of an anatomical shoulder implant inserted in 1998. Polyet...

متن کامل

Polyethylene Wear in Anatomic and Reversed Shoulder Prostheses

INTRODUCTION: Polyethylene wear is a recurrent problem in joint arthroplasty. In addition to permanent deformation or complete destruction of the component, small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. In anatomic total shoulder arthroplast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 19 7  شماره 

صفحات  -

تاریخ انتشار 2010