Ability of the digene hybrid capture II test to identify Chlamydia trachomatis and Neisseria gonorrhoeae in cervical specimens.
نویسندگان
چکیده
The Digene Hybrid Capture II (HCII CT/GC) test is a combination test designed to detect Chlamydia trachomatis and Neisseria gonorrhoeae in a single specimen. It is a nucleic acid hybridization test which uses signal amplification to increase sensitivity. We compared its performance to that of culture on cervical specimens from 1,370 women. Direct fluorescent-antibody assay was used to resolve discrepant results for C. trachomatis. Samples were collected with a proprietary cervical brush or with endocervical swabs. The HCII CT/GC test proved to be sensitive and specific in detecting these organisms. Compared to N. gonorrhoeae culture, it had a sensitivity of 93% (87/94) and a specificity of 98.5% (1,244/1,263). Compared to C. trachomatis culture, the sensitivity was 97.7% (129/132) and specificity was 98.2% (1,216/1,238). Testing of some specimens with discrepant results by PCR suggested that the test would actually prove to be even more specific if it were compared to a nucleic acid amplification test (NAAT). The sensitivity of C. trachomatis culture was somewhat less, at 88.6% (117/132). The endocervical brush appeared to be better than Dacron swabs for collecting specimens. The HCII CT/GC test offers an attractive format that allows simultaneous detection of C. trachomatis and N. gonorrhoeae with a single specimen. An initial positive result is followed by repeat tests with probes to identify chlamydiae or gonococci. This test is more sensitive than C. trachomatis culture and is at least as sensitive as culture for gonococci. It deserves further evaluation and comparison with NAATs and may well offer an attractive alternative for diagnosis and screening of these infections.
منابع مشابه
Evaluation of the digene hybrid capture II CT-ID test for detection of Chlamydia trachomatis in endocervical specimens.
The performance characteristics of the new signal amplification-based Hybrid Capture (HC) II CT-ID test system (Digene, Silver Spring, Md.) with endocervical specimens were compared to those of tissue culture and PCR (AMPLICOR CT PCR; Roche Molecular Systems, Branchburg, N.J.) for detection of Chlamydia trachomatis in 587 women. HC II CT-ID identified 62 of 65 confirmed C. trachomatis-positive ...
متن کاملPrevalence of human papillomavirus, Chlamydia trachomatis, and Neisseria gonorrhoeae in commercial sex workers in Japan.
OBJECTIVE We used the hybrid capture assays to investigate the prevalence of human papillomavirus (HPV), Chlamydia trachomatis and Neisseria gonorrhoeae among commercial sex workers in Tokyo. METHODS Five hundred forty-six consecutive commercial sex workers (CSW) who visited an STD clinic for STD checkup in 1998 and 1999 were studied. A control group consisted of 233 consecutive women who vis...
متن کاملComparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.
Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...
متن کاملComparing first-void urine specimens, self-collected vaginal swabs, and endocervical specimens to detect Chlamydia trachomatis and Neisseria gonorrhoeae by a nucleic acid amplification test.
We set out to determine the prevalences of Chlamydia trachomatis and Neisseria gonorrhoeae by ligase chain reaction as well as to determine the prevalence of Trichomonas vaginalis by culture in a large and diverse national sample of non-health-care-seeking young women entering the military; we also sought to compare the abilities of three different techniques of collecting specimens (first-void...
متن کاملMultiplex AMPLICOR PCR Screening for Chlamydia trachomatis and Neisseria gonorrhoeae in Women Attending Non-Sexually Transmitted Disease Clinics
A new PCR kit (AMPLICOR CT/NG; Roche Diagnostic Systems, Inc., Branchburg, N.J.) was used as a screening tool for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine (FVU) specimens from 3,340 asymptomatic women attending European health care units for contraceptive advice or pregnancy termination. All samples were kept frozen (220°C) prior to testing. Chlamydia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 37 11 شماره
صفحات -
تاریخ انتشار 1999