Lossy compression should not be used in certain imaging applications such as chest radiography. Against the proposition.
نویسنده
چکیده
Computational techniques are frequently used to compress image data so that transmission and storage requirements are reduced. If the computational techniques result in no loss in image resolution, the technique is referred to as lossless compression. Greater compression of data may yield some loss in spatial or temporal resolution, and is referred to as lossy compression. In some radiologic examinations [e.g., gastrointestinal (GI) studies], some resolution loss may be tolerable, whereas in others (chest examinations and mammography) it conceivably could result in missed pathology. Without lossy compression, however, data requirements can be overwhelming for transmission, storage and retrieval of images such as chest films. The unanswered question, addressed in this Point/Counterpoint issue, is whether some degree of lossy compression can be tolerated in chest radiography.
منابع مشابه
Visually Lossless Threshold: JPEG 2000 compression of Digital Chest Radiographs
radiologic examination and they account for a large portion of medical image data. For example, 16,110 chest radiographs were performed, resulting in a data volume of 229.9 gigabytes accumulated at the Seoul National University Bundang Hospital in September 2009. Irreversible (“lossy”) image compression appears to be an immediate and effective means to reduce operational costs on transmission a...
متن کاملEndobronchial Tuberculosis and Chest Radiography
Endobronchial tuberculosis and chest radiography I read, with interest, the article entitled “Clinical and Para-clinical Presentations of Endobronchial Tuberculosis” by Ahmadi Hoseini H. S. et al. (1) published in this journal. I would like to focus on some details about the chest X-ray of patients as elaborated by the authors in the results section. Accordingly, the findings of chest radiograp...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملParallel Algorithms for Entropy-Coding Techniques
With the explosion of imaging applications, and due to the massive amounts of imagery data, data compression is essential. Lossless compression, also called entropy coding, is of special importance because not only it serves as a stand-alone system for certain applications such as medical imaging, it also is an inherent part of lossy compression. Therefore, fast entropy coding/decoding algorith...
متن کاملEvaluation of the Influence of Exposure Index on Image Quality and Radiation Dose
Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 26 9 شماره
صفحات -
تاریخ انتشار 1999