Right ventricular pacing is associated with impaired overall survival, but not with an increased incidence of ventricular tachyarrhythmias in routine cardioverter/defibrillator recipients with reservedly programmed pacing.

نویسندگان

  • Martin Stockburger
  • Oezlem Celebi
  • Alice Krebs
  • Thomas Knaus
  • Aischa Nitardy
  • Dirk Habedank
  • Rainer Dietz
چکیده

AIMS Data from previous defibrillator studies raised concern about right ventricular pacing (RVP) promoting heart failure progression and mortality in implantable cardioverter/defibrillator (ICD) patients. The present observational study re-examined the association of RVP, survival, and ventricular tachyarrhythmias/ventricular fibrillation (VT/VF) in routine ICD patients with restrictively programmed pacing. METHODS AND RESULTS In 213 ICD patients [183 men, left ventricular ejection fraction (LVEF) 37 +/- 15%, follow-up 37 +/- 18 months, no advanced atrioventricular (AV) block], the RVP proportion, survival, and the time to a first appropriate VT/VF episode were assessed. Electrograms were validated and the overall survival was determined. The RVP prevalence was dichotomized at > or = 30% (high RVP) vs. <30% (low RVP). High RVP (RVP 94%, n = 24) and low RVP (RVP 0%, n = 189) patients had similar LVEF, underlying heart disease, ICD indication, and medication. Multivariate Cox regression showed no difference in survival without appropriate VT/VF treatment [odds ratio (OR): 0.92, 95% confidence interval (CI): 0.41-2.04, P = 0.83]. Overall survival was significantly more favourable in low RVP patients (OR: 0.34, CI: 0.13-0.91, P = 0.03). CONCLUSION Frequent RVP is associated with impaired survival in ICD patients despite conservative pacing settings. Implantable cardioverter/defibrillator patients requiring concomitant bradycardia pacing should be cared for with particular attention to clinical worsening. Right ventricular pacing prevention and alternative modalities of ventricular pacing need prospective evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trouble Shooting of ICD Therapy: Inappropriate Shock

Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...

متن کامل

CARDIOVASCULAR MEDICINE Incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias in high risk coronary patients and prophylactic implantation of a defibrillator

Objectives: To assess the incidence and electrophysiological characteristics of spontaneous ventricular tachyarrhythmias after implantable cardioverter-defibrillator (ICD) implantation for primary prevention. Design: Prospective observational study. Patients: 41 consecutive patients, who fulfilled MADIT (multicenter automatic defibrillator implantation trial) I criteria, except for suppressibil...

متن کامل

Biventricular pacing diminishes the need for implantable cardioverter defibrillator therapy. Ventak CHF Investigators.

OBJECTIVES We sought to test the postulate that biventricular pacing diminishes the need for appropriate tachycardia therapy. We reviewed the frequency of therapy in patients, serving as their own controls, who were enrolled in the Ventak CHF (congestive heart failure) biventricular pacing study. BACKGROUND It is well established that both acute and chronic CHF contribute to the need for tach...

متن کامل

The implantable cardioverter defibrillator.

Implantable cardioverter defibrillators (ICDs) have evolved from the treatment of last resort to the gold standard therapy for patients at high risk for ventricular tachyarrhythmias. High-risk patients include those who have survived life-threatening arrhythmias, and individuals with cardiac diseases who are at risk for such arrhythmias, but are symptomless. Use of an ICD will affect the patien...

متن کامل

Incidence and clinical relevance of slow ventricular tachycardia in implantable cardioverter-defibrillator recipients: an international multicenter prospective study.

BACKGROUND This study aims to assess the incidence and clinical relevance of slow ventricular tachycardia (VT) and the effectiveness and/or deleterious effects of antitachycardia pacing in slow VT in implantable cardioverter-defibrillator recipients. METHODS AND RESULTS This multicenter prospective randomized study included 374 patients (326 men) without prior history of slow VT (<148 bpm) im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 11 7  شماره 

صفحات  -

تاریخ انتشار 2009