An Experimental Research on Bone Drilling Temperature in Orthopaedic Surgery
نویسندگان
چکیده
The bone drilling temperature fields under different cutting parameters and cooling modes were experimental researched by using common twist drill, diamond punching pin, diamond bullet-like grinding head and diamond spherical grinding head. Three cooling modes were applied, namely, natural air cooling, normal saline pouring cooling and normal saline spray cooling. K-thermocouple was used to measure temperature in bone hole. Results showed that the drill shape could influence drilling temperature greatly. The maximum drilling temperature of diamond spherical grinding head is 46.31°C. The maximum drilling temperature of common twist drill is 42.1°C and that of diamond bullet-like grinding head is 38.29°C. The drilling temperatures at drill speed is under 560 r/min, 900 r/min, 1,250 r/min and 2,100 r/min are 38.84°C, 41.1°C, 43.84°C and 46.31°C. This reflects that under same of other drilling parameters, drilling temperature increases with the increase of drill speed. The maximum bone drilling temperatures of diamond punch pin under 2,100 r/min speed of mainshaft and air cooling conditions vary as feed speed increase firstly and then decrease. The normal saline spray cooling has the lowest maximum drilling temperature of (29.34°C) at same depth, following by normal saline pouring cooling of (32.45°C) and air cooling of (40.28°C) successively. The normal saline spray cooling has the best cooling effect, followed by normal saline pouring cooling and air cooling successively.
منابع مشابه
Modelling and optimization of temperature in orthopaedic drilling: an in vitro study.
This present investigation uses the Taguchi and response surface methodology (RSM) for modelling and optimization of the temperature produced during bone drilling. The drilling of bone is a common procedure in orthopaedic surgery to produce hole for screw insertion to fixate the fracture devices and implants. A major problem which is encountered during such a procedure is the increase in temper...
متن کاملOptimization of Orthopaedic Drilling: a Taguchi Approach
Bone drilling is a common procedure to prepare an implant site during orthopaedic surgery. An increase in temperature during such a procedure can result in thermal ostenecrosis which may delay healing or reduce the stability of the fixation. Therefore it is important to minimize the thermal invasion of bone during drilling. The Taguchi method has been applied to investigate the optimal combinat...
متن کاملBiomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: An Animal in Vitro Study
Background: The present study was conducted to quantify the relationships between bone drilling process parameters(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force andmaximum temperature).Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,in...
متن کاملTemperature effects in the drilling of human and bovine bone
Bone is an anistropic material, the drilling of which is an essential part of internal ®xation in orthopaedic and trauma surgery. Some research has been carried out into the drilling of bone, but there are no de®nitive recommendations available on the most suitable drill shape or on the optimum drilling speed that should be used in surgical practice. The heat generated during the drilling of bo...
متن کاملA new thermal model for bone drilling with applications to orthopaedic surgery.
This paper presents a new thermal model for bone drilling with applications to orthopaedic surgery. The new model combines a unique heat-balance equation for the system of the drill bit and the chip stream, an ordinary heat diffusion equation for the bone, and heat generation at the drill tip, arising from the cutting process and friction. Modeling of the drill bit-chip stream system assumes an...
متن کامل