Evidence-based research is increasingly aimed at differentiating between no proof of difference (failed demonstration of superiority) and proof of no difference (demonstration of equivalence). The latter requires that equivalence margins are incorporated in the analysis of outcomes. We applied an analysis of equivalence to study the incremental benefit of newer-generation vs earlygeneration drug-eluting stents (DES) in women receiving percutaneous coronary intervention. The clinical material was derived from published data. Our equivalence testing was focused on the end-point of target-lesion revascularisation (TLR). Results were expressed as rate differences (RDs), while the equivalence margins (±2.9%) were derived from the statistical power calculations of a recent trial. Our results clearly indicated that, in women, there was an equivalent effectiveness between newer-generation and early-generation of DES.
منابع مشابه
Multiple Stent Fractures After Everolimus-Eluting Stent Implantation Causing Acute Myocardial Infarction: A Case Report.
Stent fracture is an uncommon complication of drug-eluting stent implantation, but it has a clinical significance because of its potential association with adverse cardiac events such as in-stent restenosis, target lesion revascularization, and stent thrombosis. Multiple stent fractures account for a small proportion, but they may lead to more serious complications. Newer generation drug-elutin...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملBaremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...
متن کاملStent thrombosis: no longer an issue with newer-generation drug-eluting stents?
Drug-eluting stents (DES) were introduced to address the major limitation of bare metal stents (BMS), namely exuberant neointimal hyperplasia leading to clinical restenosis, which occurred in up to 30% of patients. Sirolimuseluting stents (SES) and paclitaxel-eluting stents (PES)— referred to as early generation DES—by means of controlled release of antiproliferative drugs had a major impact on...
متن کاملInterventional Cardiology Very Late Coronary Stent Thrombosis of a Newer-Generation Everolimus-Eluting Stent Compared With Early-Generation Drug-Eluting Stents A Prospective Cohort Study
Background—Early-generation drug-eluting stents releasing sirolimus (SES) or paclitaxel (PES) are associated with increased risk of very late stent thrombosis occurring 1 year after stent implantation. It is unknown whether the risk of very late stent thrombosis persists with newer-generation everolimus-eluting stents (EES). Methods and Results—We assessed the risk of stent thrombosis in a coho...
متن کامل