Use of susceptibility mapping to detect suspicious dark rim artefacts during perfusion MRI

نویسندگان

  • G. Varma
  • T. Lockie
  • J. Senegas
  • S. Keevil
  • S. Plein
  • T. Schaeffter
چکیده

G. Varma, T. Lockie, J. Senegas, S. Keevil, S. Plein, and T. Schaeffter Division of Imaging Sciences, King's College London, London, United Kingdom, Cardiovascular Division, King's College London, London, United Kingdom, Philips Research Europe, Hamburg, Germany, Medical Physics, Guy's & St Thomas' NHS Foundation Trust, London, United Kingdom, Academic Unit of Cardiovascular Research, University of Leeds, Leeds, United Kingdom

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High spatial resolution myocardial perfusion cardiac magnetic resonance for the detection of coronary artery disease

AIMS To evaluate the feasibility and diagnostic performance of high spatial resolution myocardial perfusion cardiac magnetic resonance (perfusion-CMR). METHODS AND RESULTS Fifty-four patients underwent adenosine stress perfusion-CMR. An in-plane spatial resolution of 1.4 × 1.4 mm(2) was achieved by using 5× k-space and time sensitivity encoding (k-t SENSE). Perfusion was visually graded for 1...

متن کامل

Through-plane dark-rim artefacts in 3D first-pass myocardial perfusion

Background The dark-rim artefact (DRA) is well known in 2D firstpass perfusion (FPP). The in-plane features of DRA are understood, but DRA has not been examined along the second phase-encoding (partition) direction for 3D FPP. The Gibbs contribution to DRAs in 2D FPP is minimised by finer resolution, but low through-plane resolutions of 3D FPP imply risk of partition axis DRAs. We investigated ...

متن کامل

MRI features of intracerebral hemorrhage within 2 hours from symptom onset.

BACKGROUND AND PURPOSE MRI has been increasingly used in the evaluation of acute stroke patients. However, MRI must be able to detect early hemorrhage to be the only imaging screen used before treatment such as thrombolysis. Susceptibility-weighted imaging, an echo-planar T2* sequence, can show intracerebral hemorrhage (ICH) in patients imaged between 2.5 and 5 hours from symptom onset. It is u...

متن کامل

Adenosine stress CMR with variable density spiral pulse sequences accurately detects CAD with minimal dark-rim artifacts

Background Adenosine stress CMR perfusion imaging has numerous advantages over competing modalities for assessing CAD demonstrating high diagnostic and prognostic utility. However, adenosine stress CMR perfusion imaging is limited by motion-induced dark-rim artifacts (DRA) which may be mistaken for true perfusion abnormalities. We have previously demonstrated that a high-resolution variable-den...

متن کامل

Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.

BACKGROUND Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008