Investigation of Beam Alignment Monitor Technologies for the LCLS FEL Undulator?

نویسندگان

  • R. Hettel
  • R. Carr
  • C. Field
  • D. Martin
چکیده

To maintain gain in the proposed 100 m long linac-driven Linac Coherent Light Source (LCLS) Free Electron Laser (FEL) undulator, the electron and photon beams must propagate colinearly to within -5 urn rms over distances comparable to the 11.7 m FEL gain length in the 6 mm diameter undulator vacuum chamber. We have considered a variety of intercepting and non-intercepting position monitor technologies to establish and maintain this beam alignment. We present a summary discussion of the applicability and estimated performance of monitors detecting synchrotron radiation, transition and diffraction radiation, fluorescence, photoemission or bremsstrahlung from thin wires, Compton scattering from laser beams, and image currents from the electron beam. We conclude that: 1) non-intercepting rf cavity electron BPMs, together with a beam-based alignment system, are best suited for this application; and 2) insertable, intercepting wire monitors are valuable for rough alignment, for beam size measurements, and for simultaneous measurement of electron and photon beam position by detecting bremsstrahlung from electrons and diffracted x-rays from the photon heam.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lcls Undulator Commissioning, Alignment, and Performance *

The LCLS x-ray FEL has recently achieved its 1.5Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 μm) through the LCLS und...

متن کامل

Girder Support Scheme for the LCLS Undulator System

Differential settlement of the foundation of the LCLS Undulator Hall will cause quadrupoles to move and the electron beam trajectory to distort. The resulting phase errors will decrease the FEL power and require time consuming beam-based alignment sessions to correct. By supporting quadrupoles on girders, with three quadrupoles to a girder, the foundationmotion induced phase error between the b...

متن کامل

Linac Coherent Light Source Undulator Rf Bpm System *

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of...

متن کامل

Phase Slip in an Undulator with Pole and Bpm Errors

A statistical analysis of a corrected electron trajectory through a planar FEL undulator is used to predict the optimal beam position monitor (BPM) spacing. The undulator is composed of modular sections, each containing many dipoles with random field and roll angle errors. Located between each section are inaccurate BPMs, steering correctors, and possibly quadrupole magnets. An analytical formu...

متن کامل

SASE FEL Saturation Characterization at the ATF

After successful completion of the High Gain Harmonic Generation (HGHG) free electron laser (FEL) experiment [1,2] at the Accelerator Test Facility (ATF), R&D toward future light sources at the NSLS achieved another milestone on March 17, 2001 when the visible-infrared self-amplified spontaneous emission amplifier (VISA) experiment at the ATF achieved saturation. The VISA Self Amplified Spontan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998