Electric-field control of the tautomerization and metal ion binding reactivity of 8-hydroxyquinoline immobilized to an electrode surface.
نویسندگان
چکیده
Surface-enhanced Raman scattering (SERS) spectra of a metal-complexing ligand, immobilized to a silver electrode surface, exhibits significant structural changes upon application of modest potentials. A detailed spectroscopic investigation shows that the potential applied to the electrode surface governs the tautomerization equilibrium of the immobilized ligand, p-((8-hydroxyquinoline)azo)benzenethiol (SHQ). Potential-dependent SERS spectra reveal that SHQ exists predominantly in a keto-hydrazone tautomeric form at applied potentials that are negative of -300 mV (vs Ag/AgCl), while the enol-azo tautomer is strongly favored at potentials positive of this value. The observed switching of the tautomer population occurs within a narrow range of applied potentials, approximately 200 mV (Ag/AgCl). Electrical control over the tautomerization equilibrium of immobilized SHQ governs the reactivity of the ligand toward metal ion complexation, where the enol-azo tautomer exhibits much greater affinity for metal ion binding compared to its keto-hydrazone counterpart. Accordingly, the potential applied to the electrode can be used to influence metal ion binding of immobilized SHQ through control over the tautomerization equilibrium, to produce an electrically switchable surface for metal ion complexation. Large differences in the electric dipole moment of the two tautomers, estimated from density functional theory calculations, suggested a model where the potential dependence arises from the interaction of the ligand dipole with electric fields that exist at a polarized electrode surface. This model accurately predicts the relative tautomer populations versus applied potential, at interfacial electric fields that are consistent with previous measurements of the vibrational Stark effect at polarized interfaces. Potential applications of this technology to several areas of analytical chemistry are considered.
منابع مشابه
A Sensitive Novel Approach towards the Detection of 8-Hydroxyquinoline at Anionic Surfactant Modified Carbon Nanotube Based Biosensor: A Voltammetric Study
A rapid electrochemical technique was developed to determine 8-Hydroxyquinoline (8HQ). In the current study, the anionic surfactant Sodium lauryl sulfate (SLS) was immobilized on the multi-walled carbon nanotube (MWCNT) paste surface for the fabrication of electrode to detect 8HQ in phosphate buffer solution (PBS) of pH 7.0. The response of SLS modified carbon nanotube paste electrode (SLSMCNTP...
متن کاملEvaluation of Immobilized Metal-Ion Affinity Chromatography and Electrospray Ionization Tandem Mass Spectrometry for Recovery and Identification of Copper(II)-Binding Ligands in Seawater Using the Model Ligand 8-Hydroxyquinoline
Citation: Nixon RL and Ross ARS (2016) Evaluation of Immobilized Metal-Ion Affinity Chromatography and Electrospray Ionization Tandem Mass Spectrometry for Recovery and Identification of Copper(II)-Binding Ligands in Seawater Using the Model Ligand 8-Hydroxyquinoline. Front. Mar. Sci. 3:246. doi: 10.3389/fmars.2016.00246 Evaluation of Immobilized Metal-Ion Affinity Chromatography and Electrospr...
متن کاملDevelopment of An Immobilized Enzyme Electrode for the Determination of Sulfite Ion
An enzyme electrode was developed using the enzyme sulfite oxidase (EC1.8.3.1) immobilized onto pig intestine. Hydrogen peroxide produced was monitored amperometrically. All experimental parameters such as pH, temperature, buffer constituent concentration, were thoroughly investigated and optimized when appropriate. The response to sulfite concentration was linear in the range 5.2´...
متن کاملELECTRODE EFFECT ON FLOW CONDITIONS IN ARGON GAS METAL ARE MODELING
A two dimensional mathematical model has been developed for describing the temperature, flow, and electric fields in the are column of the Gas Metal Arc Welding (GMAW) of aluminum in argon shielding gas using axisymmetric Navier-Stokes, Maxwell, and differential thermal energy equations. The predicted results are most sensitive to the cathode spot radius and an optimum cathode spot radius exist...
متن کاملAn electrode immobilized in a graphite matrix with ion pair complex for the determination of diclofenac in pharmaceuticals
A simple, precise, rapid and low-cost potentiometric method for diclofenac determination in pharmaceuticals is proposed. A new diclofenac-sensitive electrode was constructed by incorporating the diclofenac ion pair complex with butyl rhodamine B into graphite matrix. The electrode exhibited a linear response over the concentration range of 1 × 10-4 – 5 × 10-2 mol L-1, a detection limit of 3.9×1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 80 6 شماره
صفحات -
تاریخ انتشار 2008