A comparison of four methods of tonometry: method agreement and interobserver variability.
نویسندگان
چکیده
AIM To compare the inter-method agreement in intraocular pressure (IOP) measurements made with four different tonometric methods. METHODS IOP was measured with the Goldmann applanation tonometer (GAT), Tono-Pen XL, ocular blood flow tonograph (OBF), and Canon TX-10 non-contact tonometer (NCT) in a randomised order in one eye of each of 105 patients with ocular hypertension or glaucoma. Three measurements were made with each method, and by each of two independent GAT observers. GAT interobserver and tonometer inter-method agreement was assessed by the Bland-Altman method. The outcome measures were 95% limits of agreement for IOP measurements between GAT observers and between tonometric methods, and 95% confidence intervals for intra-session repeated measurements. RESULTS The mean differences (bias) in IOP measurements were 0.4 mm Hg between GAT observers, and 0.6 mm Hg, 0.1 mm Hg, and 0.7 mm Hg between GAT and Tono-Pen, OBF, and NCT, respectively. The 95% limits of agreement were smallest (bias +/-2.6 mm Hg) between GAT observers, and larger for agreement between the GAT and the Tono-Pen, OBF, and NCT (bias +/-6.7, +/-5.5, and +/-4.8 mm Hg, respectively). The OBF and NCT significantly underestimated GAT measurements at lower IOP and overestimated these at higher IOP. The repeatability coefficients for intra-session repeated measurement for each method were +/-2.2 mm Hg and +/-2.5 mm Hg for the GAT, +/-4.3 mm Hg for the Tono-Pen, +/-3.7 mm Hg for the OBF, and +/-3.2 mm Hg for the NCT. CONCLUSIONS There was good interobserver agreement with the GAT and moderate agreement between the NCT and GAT. The differences between the GAT and OBF and between the GAT and Tono-Pen probably preclude the OBF and Tono-Pen from routine clinical use as objective methods to measure IOP in normal adult eyes.
منابع مشابه
بررسی میزان توافق بینفردی در تشخیص تغییرات غیرطبیعی سلولهای پوششی دهانه رحم در نمونههای پاپاسمیر
800x600 Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tstyle-rowband-size:0 mso-tstyle-colband-size:0 mso-style-noshow:yes mso-style-priority:99 mso-style-parent:"" mso-p...
متن کاملThe relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry.
AIMS To establish the effects of central corneal thickness (CCT) on intraocular pressure (IOP) measured with a prototype Pascal dynamic contour tonometer (DCT), to evaluate the effect of CCT and age on the agreement between IOP measured with the Pascal DCT and Goldmann applanation tonometer (GAT), and to compare the interobserver and intraobserver variation of the DCT with the GAT. METHODS GA...
متن کاملInterobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool
Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...
متن کاملA Survey on Current Methods of Carpal Height Ratio Measurement and Suggestion of a New Method
Background & Aims: Two famous methods are commonly used for the measurement of carpal height ratio. Both methods are performed on anteroposterior radiogram and have some shortcomings. We are going to introduce a new method for measuring this index in lateral view of the wrist radiogram' Methods: This cross-sectional and case-control study was conducted on 100 anteroposterior and lateral radiogr...
متن کاملComparison of handheld rebound tonometry with Goldmann applanation tonometry in children with glaucoma: a cohort study
OBJECTIVE To test agreement of two methods to measure intraocular pressure (IOP): rebound tonometry (RBT) and gold standard Goldmann applanation tonometry (GAT) in children with glaucoma. DESIGN Observational prospective cohort study. SETTING Tertiary paediatric glaucoma clinic at a single centre. PARTICIPANTS 102 individuals attending a paediatric glaucoma clinic, mean (SD) age 11.85 (3....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 89 7 شماره
صفحات -
تاریخ انتشار 2005