High-b-value diffusion-weighted MR imaging of hyperacute ischemic stroke at 1.5T.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Diffusion-weighted (DW) imaging at b = 2000 s/mm(2) offers theoretical advantages over DW imaging at b = 1000 s/mm(2) for detection of hyperacute ischemic stroke. The purpose of this study was to determine whether b = 2000 images are better than b = 1000 images for detecting and estimating the extent of diffusion change within 6 hours after stroke onset. METHODS We compared DW images obtained with a b value of 1000 s/mm(2) (TR/TE/NEX, 7500/71/1) with those obtained with a b value of 2000 s/mm(2) (TR/TE/NEX, 7500/83/2) in 94 patients examined within 6 hours of clinically suspicious hyperacute ischemic stroke (57 men, 37 women; mean age +/- SD, 62 years +/- 8; age range, 47-80 years; mean time interval +/- SD, 206 +/- 90 min). Three observers performed qualitative analysis of DW images and reached a consensus about lesion conspicuity, lesion extent, and image artifact. In the quantitative analysis of 34 patients with lesions in the territory of the middle cerebral artery, the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and volume of ischemic lesion were measured and findings of the b = 1000 and b = 2000 images were compared. RESULTS The sensitivity and specificity of b = 1000 and b = 2000 images were calculated as 94% (80/85)/ 100% (9/9) and 98% (83/85)/ 100% (9/9), respectively, relative to the presence or absence of infarction on the follow-up T2-weighted images. In three patients, hyperintense lesions were depicted only on b = 2000 images. On qualitative analysis, lesions were more conspicuous and larger on b = 2000 images in 23 and 11 patients, respectively. On quantitative analysis, as the b value increased, the mean lesion volume increased by 47% (22.1 +/- 27.9 mL at b = 1000 s/mm(2) versus 32.5 +/- 36.5 mL at b = 2000 s/mm(2), P < .001, n = 34). As the b value increased, mean SNR decreased both in the lesion and in the contralateral normal area by 17% and 28%, respectively, but the mean CNR increased by 23% (8.7 +/- 6.4 at b = 1000 s/mm(2) versus 10.7 +/- 6.5 at b = 2000 s/mm(2), P < .001, n = 34). CONCLUSION DW images acquired with a b value of 2000 s/mm(2) were better than DW images acquired with a b value of 1000 s/mm(2) for the detection and estimation of the extent of diffusion change in patients examined within 6 hours of ischemic stroke onset.
منابع مشابه
Hyperacute ischemic stroke missed by diffusion-weighted imaging.
We present two cases of hyperacute ischemic stroke that were initially missed by diffusion-weighted imaging; abnormalities in locations corresponding to focal neurologic deficits were discovered by MR angiography and perfusion-weighted imaging. Within hours, follow-up diffusion-weighted scans revealed partial conversion of the hypoperfused regions to complete stroke. These cases illustrate the ...
متن کاملMetabolic counterpart of decreased apparent diffusion coefficient during hyperacute ischemic stroke: a brain proton magnetic resonance spectroscopic imaging study.
BACKGROUND AND PURPOSE Recent studies have shown that the brain ischemic area defined by the map of decreased apparent diffusion coefficient (ADC) obtained by diffusion-weighted imaging (DWI) during the first hours of ischemic stroke includes a significant part of ischemic penumbra. We hypothesize that the misjudgment of the final infarct size by ADC mapping may be related to a restricted abili...
متن کاملDiffusion kurtosis is sensitive to hyperacute cerebral ischemia and increases with ischemic progression without renormalization
Introduction The outcome of stroke treatment relies in large part on reliable staging of ischemic tissue, and it remains a challenge to find the optimal MR techniques as such. Owing to the high sensitivity and specificity of conventional MR diffusion-weighted imaging in ischemic tissue delineation, additional clinically relevant information regarding ischemic tissue microstructure can be probed...
متن کاملFeasibility and practicality of MR imaging of stroke in the management of hyperacute cerebral ischemia.
BACKGROUND AND PURPOSE Neuroimaging techniques such as diffusion- and perfusion-weighted MR imaging have been proposed as tools for advanced diagnosis in hyperacute ischemic stroke. There is, however, substantial doubt regarding the feasibility and practicality of applying MR imaging for the diagnosis of stroke on a routine basis, especially with respect to possible delay for specific treatment...
متن کاملVarious patterns of perfusion-weighted MR imaging and MR angiographic findings in hyperacute ischemic stroke.
BACKGROUND AND PURPOSE Various clinical subtypes of patients presenting with sudden-onset ischemic stroke have been recognized, but classification of those types is not simple. We identified various patterns of perfusion-weighted MR imaging and MR angiographic findings in hyperacute ischemic stroke with relation to clinical outcomes. METHODS Twelve patients with symptoms of acute ischemic str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2005