Intraocular lens power calculations in the triple procedure.
نویسندگان
چکیده
When a triple procedure is planned, calculation of the intraocular lens becomes a problem. Postoperative corneal power bears no relation to preoperative power, and the axial length of the globe also changes. A prospective study of 24 keratoplasties revealed a close relationship between postoperative corneal power and donor corneal power. Changes in axial length were found to be too small to produce errors in calculation. The equation derived in this series to describe the relation between postoperative and donor corneal power is applicable only when certain trephine sizes are used and when the recepient cornea is not excessively scarred.
منابع مشابه
Optimization of intraocular lens constant improves refractive outcomes in combined endothelial keratoplasty and cataract surgery.
PURPOSE To evaluate the accuracy of intraocular lens (IOL) power calculations with A-constant optimization in Descemet's stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and intraocular lens implantation (DSAEK triple procedure). DESIGN Retrospective case series. PARTICIPANTS Thirty eyes of 22 patients with Fuchs' endothelial dystrophy who underwent the...
متن کاملIntraocular lens power calculation following laser refractive surgery
Refractive outcomes following cataract surgery in patients that have previously undergone laser refractive surgery have traditionally been underwhelming. This is related to several key issues including the preoperative assessment (keratometry) and intraocular lens power calculations. Peer-reviewed literature is overwhelmed by the influx of methodology to manipulate the corneal or intraocular le...
متن کاملIntraocular lens power calculatio n after corneal refractive surgery
Current Opinion in Ophthalmology 2008, 19:357–362 Purpose of review Corneal refractive procedures have become increasingly popular over the past decade allowing patients to have excellent uncorrected visual acuity and spectacle independence. As these individuals mature, many will eventually undergo cataract surgery. With the advances in modern cataract surgery and lens implant technology, parti...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 73 9 شماره
صفحات -
تاریخ انتشار 1989