[Measurement of ethylene oxide at a medical sterilization site].

نویسندگان

  • F Asakawa
  • F Jitsunari
  • S Suna
  • Y Manabe
  • I Fukunaga
  • N Takeda
چکیده

Although ethylene oxide gas is widely used as a sterilizing agent for medical instruments because of its disinfection property, the effects of its use in medical settings have not been clarified. In the present study, we measured the ethylene oxide gas concentration (EOGC) within a hospital sterilization unit and in the ambient air near the unit. Before the sterilizer was turned on (about 9:00), the ambient air EOGC was below the detection limit (0.1 ppm). When the door was opened to place the instruments in the sterilizer, the maximum EOGC near the door of the sterilizer was 1.71 ppm. Before the sterilizer door was opened, the residual EOGC within the sterilizer was 0.10-24.56 ppm. During the operation of the sterilizer (9:00-17:00), ethylene oxide gas could not be detected in the air near the unit. When the sterilizer door was opened at the end of the routine operation of the sterilizer (about 17:00), EOGC near the door was 2.10-2.73 ppm. After the door was closed, the ambient air EOGC level was 0.5-0.57 ppm. These findings indicate that the personnel near the unit were exposed to ethylene oxide gas for about 15 min during the transfer. However, no ethylene gas could be detected by the ethylene oxide gas monitor (3M Co., #3551). The finding that EOGC in sterilized medical instruments after 24 h of aeration was about 2 ppm also suggests that the personnel using these instruments were exposed to ethylene oxide gas.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dense CO2: An Innovative Method for Sterilization of Venous Catheters at Low Temperature

Venous catheters are important medical devices which are more and more employed in medical treatment. After use, they are currently not re-used, a practice which is very expensive due to their cost. For this reason it is very interesting to be able to set up a sterilizing technology that permit to re-use them without changing their physical properties and the microbial adhesion. The methods usu...

متن کامل

Sorption processes in gas sterilization in the medical sector.

Sorption of ethylene oxide during and after gaseous sterilization is influenced by numerous factors. It was found that ethylene oxide desorption not only depends on material to be fumigated but also to a considerable degree on the wrapping material. Although polyethylene, polyamide (nylon), polytetrafluoroethylene (Teflon), silicone, aluminum, and glass beads contained no quantities of ethylene...

متن کامل

Sterilization by ethylene oxide.

Although sterilization by steam under pressure and by hot air are procedures which are now well understood and efficient when properly conducted, there is an increasing number of objects in medical or surgical use which are too heat labile to be so treated. It is for such items as plastic catheters, disposable plastic syringes, and prostheses that ethylene oxide has been proposed as a convenien...

متن کامل

Improved Sterilization of Sensitive Biomaterials with Supercritical Carbon Dioxide at Low Temperature

The development of bio-resorbable implant materials is rapidly going on. Sterilization of those materials is inevitable to assure the hygienic requirements for critical medical devices according to the medical device directive (MDD, 93/42/EG). Biopolymer-containing biomaterials are often highly sensitive towards classical sterilization procedures like steam, ethylene oxide treatment or gamma ir...

متن کامل

Portable ethylene oxide sterilization chamber.

A portable ethylene oxide sterilization chamber was designed, constructed, and tested for use in the sterilization of embolectomy catheters. The unit can accommodate catheters up to 40 inches (101.6 cm) in length and can be operated for less than 4 cents per cycle. A constant concentration of 500 mg of ethylene oxide per liter of space and holding periods of 4 and 6 hr at 43 and 22 C, respectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sangyo igaku. Japanese journal of industrial health

دوره 35 5  شماره 

صفحات  -

تاریخ انتشار 1993