Improving the quality of transvaginal ultrasound scan by simulation training for general practice residents
نویسندگان
چکیده
Background Ultrasonography (US) is an essential tool for the diagnosis of acute gynecological conditions. General practice (GP) residents are involved in the first-line management of gynecologic emergencies. They are not familiar with US equipment. Initial training on simulators was conducted.The aim of this study was to evaluate the impact of simulation-based training on the quality of the sonographic images achieved by GP residents 2 months after the simulation training versus clinical training alone. Methods Young GP residents assigned to emergency gynecology departments were invited to a one-day simulation-based US training session. A prospective controlled trial aiming to assess the impact of such training on TVS (transvaginal ultrasound scan) image quality was conducted. The first group included GP residents who attended the simulation training course. The second group included GP residents who did not attend the course. Written consent to participate was obtained from all participants. Images achieved 2 months after the training were scored using standardized quality criteria and compared in both groups. The stress generated by this examination was also assessed with a simple numeric scale. Results A total of 137 residents attended the simulation training, 26 consented to participate in the controlled trial. Sonographic image quality was significantly better in the simulation group for the sagittal view of the uterus (3.6 vs 2.7, p = 0.01), for the longitudinal view of the right ovary (2.8 vs 1.4, p = 0.027), and for the Morrison space (1.7 vs 0.4, p = 0.034), but the difference was not significant for the left ovary (2.9 vs 1.7, p = 0.189). The stress generated by TVS after 2 months was not different between the groups (6.0 vs 4.8, p = 0.4). Conclusion Simulation-based training improved the quality of pelvic US images in GP residents assessed after 2 months of experience in gynecology compared to clinical training alone.
منابع مشابه
The effect of dyad versus individual simulation‐based ultrasound training on skills transfer
CONTEXT Dyad practice may be as effective as individual practice during clinical skills training, improve students' confidence, and reduce costs of training. However, there is little evidence that dyad training is non-inferior to single-student practice in terms of skills transfer. OBJECTIVES This study was conducted to compare the effectiveness of simulation-based ultrasound training in pair...
متن کاملI-25: Management of Hydrosalpinx in ART
Hydrosalpinx, is one of the severe manifestations of tubal disease, is associated with significantly lower implantation and pregnancy rates, increased spontaneous abortion and ectopic pregnancy.This condition is usually due to PID but may also result from peritonitis of any cause or tubal damage from previous surgery.The mechanism for poor outcome in patients undergoing IVF is not yet clear. Ma...
متن کاملSustained effect of simulation-based ultrasound training on clinical performance: a randomized trial
OBJECTIVE To study the effect of initial simulation-based transvaginal sonography (TVS) training compared with clinical training only, on the clinical performance of residents in obstetrics and gynecology (Ob-Gyn), assessed 2 months into their residency. METHODS In a randomized study, new Ob-Gyn residents (n = 33) with no prior ultrasound experience were recruited from three teaching hospital...
متن کاملAssessment of transvaginal ultrasonography accuracy in the diagnosis of uterine pathologies in women with abnormal uterine bleeding
Abstract Background: The most common causes of abnormal uterine bleeding in women of reproductive age are uterine structural abnormalities. There are several modalities for the examination of abnormal uterine bleeding, including transvaginal ultrasound and hysteroscopy. In this study, we aimed to investigate the diagnostic accuracy of hysteroscopy versus transvaginal ultrasound in the diagnosis...
متن کاملTransvaginal ultrasound in pregnancy: its acceptability to women and maternal psychological morbidity.
OBJECTIVES To assess the acceptability to women of antenatal transvaginal ultrasound scans; to compare the characteristics of women who accept the offer of a transvaginal scan with those who decline; to establish the prevalence of any psychological morbidity associated with the scan. METHODS The study was a cross-sectional questionnaire survey. Women were recruited from two hospitals in South...
متن کامل