The Influence of the Enzyme Membrane Thickness on the Response of Amperometric Biosensors

نویسندگان

  • Romas Baronas
  • Feliksas Ivanauskas
  • Juozas Kulys
چکیده

A mathematical model of amperometric biosensors has been developed. The model is based on non-stationary diffusion equations containing a non-linear term related to Michaelis-Menten kinetics of the enzymatic reaction. Using digital simulation, the influence of the thickness of enzyme membrane on the biosensor response was investigated. The digital simulation of the biosensor operation showed the non-monotonous change of the maximal biosensor current versus the membrane thickness at the various maximal enzymatic rates. Digital simulation was carried out using the finite difference technique. Results of the numerical simulation was compared with known analytical solutions. This paper presents a framework for selection of the membrane thickness, ensuring the sufficiently stable sensitivity of a biosensor in a required range of the maximal enzymatic rate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computational Modelling of Membrane Biosensors Acting in Stirred and Non-stirred Solutions

This paper presents mathematical models of potentiometric as well as amperometric biosensors, based on an electrode covered with an enzyme membrane. The models involve three regions: the enzyme layer where enzyme reaction as well as mass transport by diffusion takes place, a diffusion limiting region where only the diffusion takes place, and a convective region, where the analyte concentration ...

متن کامل

AMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE

The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...

متن کامل

A Physico-Mathematical Model for Bisubstrate Enzyme Membrane Electrodes

A physic-mathematical model has been developed that is suitable for biosensors incorporating membranes and bisubstrate enzymes. The set of equations regarding the transport of reactants across the membrane, the bisubstrate enzymatic reaction, back diffusion of reactants and reaction products, are written down and simultaneously solved and transient response of the electrode is determined as...

متن کامل

Mathematical Modeling of the Amperometric Response to Glucose of Glucose Oxidase Films Deposited by AC-Electrophoresis

Previous work illustrated that glucose oxidase (GOx) could be deposited on conducting substrates using asymmetrical alternating current electrophoretic deposition (AC-EPD) to form thick enzyme layers suitable for the manufacturing of highly active biosensors. Here, we modeled the amperometric response of GOx layers to glucose as a function of the thickness of the enzyme layer. The model is base...

متن کامل

Ascorbic Acid Determination by an Amperometric Ascorbate Oxidase-based Biosensor

The aim of this work is to develop a method for ascorbic acid determination in some fruit juices, by using an ascorbate oxidase-based amperometric enzyme electrode. The enzyme was immobilized on a nylon (Biodyne A) membrane by glutaraldehyde linking. The enzyme-membrane was consecutively attached to the polyethylene membrane of a Clark oxygen electrode, which functioned as transducer. The analy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003