Measurement of late-night salivary cortisol with an automated immunoassay system.
نویسندگان
چکیده
BACKGROUND Measurement of late-night salivary cortisol concentrations is increasingly used as a screening test in suspected Cushing's syndrome. Cortisol concentrations are typically extremely low in late-night samples and discordant assay-specific reference ranges have been reported. Therefore, the aim of our study was to assess the analytical performance of the first automated cortisol immunoassay specified for salivary measurements and to establish late-night sampling reference-range data for this test. METHODS Salivary cortisol was measured using the Roche Cobas Cortisol assay (Roche Diagnostics). Five salivary pools in different concentration ranges were used to assess the inter-assay imprecision of this test in a two-centre evaluation protocol including two reagent lots. Linearity was tested by serial dilution. Salivary samples were obtained at 23:00 h from 100 apparently healthy volunteers using a commercially available salivary sampling device (Salivette, Sarstedt). A subset of 20 samples was used for method comparison with isotope dilution liquid chromatography-tandem mass spectrometry. RESULTS Inter-assay coefficients of variation (n=20) between 11.6% and 40.4% were found for mean cortisol concentrations between 12.9 and 2.6 nmol/L, with an estimated functional sensitivity of approximately 5.0 nmol/L. The test also gave linear results in the lowest concentration range between 1.0 and 8.3 nmol/L. Mean late-night salivary cortisol of 5.0 nmol/L was found for healthy individuals; the absolute range was 1.4-16.7 nmol/L, and the 95th percentile was 8.9 nmol/L. Substantially lower concentrations were found with isotope dilution LC-MS/MS compared to immunoassay results (mean concentrations 1.8 and 4.4 nmol/L, respectively). CONCLUSIONS The automated assay investigated was found to offer acceptable analytical performance in the very low concentration range required for late-night salivary cortisol, despite a very short turn-around time. Using this assay, late-night salivary cortisol concentrations below 8.9 nmol/L are typically found in healthy volunteers.
منابع مشابه
Diurnal Salivary Cortisol following Mindfulness-Based Cognitive Therapy (MBCT) in Women with Breast Cancer: A pilot Study
ABSTRACT Background and Objectives: Cancer and its conventional treatments may bring about some psychological and health-related symptoms leading to unstable cortisol level. Since evidence has shown that mindfulness based approaches can be helpful to reduce cortisol level, we aimed at investigating the efficacy of &n...
متن کاملAutomated-immunosensor with centrifugal fluid valves for salivary cortisol measurement
Point-of-care measurement of the stress hormone cortisol will greatly facilitate the timely diagnosis and management of stress-related disorders. We describe an automated salivary cortisol immunosensor, incorporating centrifugal fluid valves and a disposable disc-chip that allows for truncated reporting of cortisol levels (<15 min). The performance characteristics of the immunosensor are optimi...
متن کاملSalivary cortisol as a diagnostic tool for Cushing's syndrome and adrenal insufficiency: improved screening by an automatic immunoassay.
BACKGROUND Salivary cortisol is increasingly used to assess patients with suspected hypo- and hypercortisolism. This study established disease-specific reference ranges for an automated electrochemiluminescence immunoassay (ECLIA). METHODS Unstimulated saliva from 62 patients with hypothalamic-pituitary disease was collected at 0800 h. A peak serum cortisol level below 500 nmol/l during the i...
متن کاملCircadian rhythm of salivary cortisol, plasma cortisol, and plasma ACTH in end-stage renal disease
OBJECTIVE Patients with end-stage renal disease (ESRD) can display the features of endogenous hypercortisolism but are difficult to evaluate for Cushing's syndrome. We evaluated the circadian rhythm of plasma compared with salivary cortisol in subjects with ESRD. DESIGN Plasma and salivary cortisol and plasma ACTH samples were drawn frequently over 24 h in an inpatient research unit in stable...
متن کاملClinical utility of late-night and post-overnight dexamethasone suppression salivary cortisone for the investigation of Cushing's syndrome.
INTRODUCTION There is a pressing need to identify diagnostic testing for Cushing's syndrome that can be achieved with ease and at low cost. This study aimed to explore the usefulness of late-night and post-overnight 1-mg dexamethasone suppression salivary cortisone, as measured by liquid chromatography-tandem mass spectrometry, for investigation of hypercortisolism. METHODS Salivary cortisone...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 44 12 شماره
صفحات -
تاریخ انتشار 2006