Characterization and mathematical correction of hemolysis interference in selected Hitachi 717 assays.

نویسندگان

  • D W Jay
  • D Provasek
چکیده

The effect of hemolysis on several assays performed with the Hitachi 717 was quantified by relating the amount of error to the concentration of hemoglobin. Hemolysis interference was judged clinically significant when analyte concentration varied by > 10% from the initial value. Hemolysis interference was significant for alkaline phosphatase, aspartate aminotransferase, alpha-amylase, bilirubin, creatine kinase, gamma-glutamyltransferase, lactate dehydrogenase, lactate dehydrogenase-1, potassium, and theophylline assays. Error (expressed in absolute terms) was linearly dependent on hemoglobin concentration and independent of the initial analyte concentration in each case, except for bilirubin and theophylline, where multiple regression analysis was required to quantify the effect. Relative error was dependent on the initial analyte concentration in all cases. Correction formulas were calculated from linear regression of absolute error vs hemoglobin concentration. Clinical application of correction formulas and mechanisms of hemolysis interference for each assay are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interferences of o-raffinose cross-linked hemoglobin in three methods for serum creatinine.

The interferences of o-raffinose cross-linked hemoglobin (Hemolink) were examined and compared in two serum creatinine methods on the Hitachi 717 [Boehringer Mannheim (BMC) and Synermed] and in an enzymatic creatinine method on the Vitros 750 (Johnson & Johnson). Interference was considered significant when the change in creatinine concentration from the control exceeded the 95% confidence limi...

متن کامل

Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.

We evaluated the effect of hemolysis, icteric discoloration, lipemia, paraproteinemia, and uremia on enzymatic methods for determining sodium, potassium, and chloride, according to the National Committee for Clinical Laboratory Standards EP7-P proposals for testing interference from endogenous substances. The sodium, potassium, and chloride assays (reagent kits supplied by Boehringer Mannheim) ...

متن کامل

Methemalbumin interference in various biochemical assays of plasma.

During intravascular hemolysis and digestion of extravasated blood, heme from hemoglobin is oxidized to hematin, hich combines with plasma proteins to form methemalbu(1-4). One case of strong methemalbuminemia (140 oI/L) associated with intravascular hemolysis has been bserved in a patient after placing of an intracardiac valve. e plasma of this patient was so brown that we became terested in t...

متن کامل

Hemolysis index to detect degree of hydroxocobalamin interference with common laboratory tests.

BACKGROUND Cyanokit® (hydroxocobalamin OHCo) is the recommended treatment for cyanide poisoning. OHCo is a red chromophore and may cause interference with some biochemical measurements. In this study, we assessed the possible interference of Cyanokit on several cooximetric and plasma biochemistry tests and then determined the possible mathematical correction for some analytes. We studied the po...

متن کامل

Effect of hemoglobin- and Perflubron-based oxygen carriers on common clinical laboratory tests.

Polymerized hemoglobin solutions (Hb-based oxygen carriers; HBOCs) and a second-generation perfluorocarbon (PFC) emulsion (Perflubron) are in clinical trials as temporary oxygen carriers ("blood substitutes"). Plasma and serum samples from patients receiving HBOCs look markedly red, whereas those from patients receiving PFC appear to be lipemic. Because hemolysis and lipemia are well-known inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 9  شماره 

صفحات  -

تاریخ انتشار 1993