Polymerizing Bone Cement can Roughen a Polyethylene Bearing Surface on Total Hip Replacement – A Surface Analysis

نویسندگان

  • Paul YF Lee
  • Phillip Alderman
  • Paul Roberts
چکیده

The tribological behaviour of the bearing surface in hip arthroplasty is greatly influenced by its surface roughness. During cemented hip arthroplasty, bone cement may contaminate the bearing surface. Hence, the aim of this study was to investigate the effect of cement polymerization on a highly cross-linked polyethylene(HCLP) bearing surface as any process influences the surface roughness of the bearing surface can have potential long term effect on the wear rate. Three new HCLP liners were used. A map of the surface topography of each liner was obtained using a white light interferometric microscope at five different locations in accordance with the standard BSEN ISO 4288:1998. Bone cement was then applied to the bearing surface and allowed to polymerise, then removed and irrigated with saline. The surface roughness measurement procedure was repeated again for all samples. The Ra results showed a 21% increase in mean surface roughness after cement contamination (p=0.01). The average Ra value pre-contamination was 190 nm while post-contamination was 230 nm. There were also changes in the surface topography observed with 3D surface mapping. Our study indicates that bone cement contamination of the HCLP surface can significantly increase its surface roughness and alter its surface topography. Surgeons should be aware of this potentially serious effect on the bearing and be vigilant to avoid bone cement contamination during arthroplasty surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strontium-containing hydroxyapatite bioactive bone cement in revision hip arthroplasty.

Clinical outcome of cemented implants to revision total hip replacement (THR) is not as satisfactory as primary THR, due to the loss of bone stock and normal trabecular pattern. This study evaluated a bioactive bone cement, strontium-containing hydroxyapatite (Sr-HA) bone cement, in a goat revision hip hemi-arthroplasty model, and compared outcomes with polymethylmethacrylate (PMMA) bone cement...

متن کامل

The temperature problem at the bone-acrylic cement interface of the total hip replacement.

Loosening of total joint replacements may be caused in part by thermal necrosis of bone in contact with the high temperature of the polymerizing PMMA acrylic cement. This study reports a method to reduce the temperature of the bone-cement interface below the temperature at which bone results in definite necrosis. By precooling the acetubular component to --84 degrees before insertion into the c...

متن کامل

The current state of bearing surfaces in total hip replacement.

We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the...

متن کامل

Ceramic-on-ceramic bearing surface and risk of revision due to dislocation after primary total hip replacement.

Dislocation is a common reason for revision following total hip replacement. This study investigated the relationship between the bearing surface and the risk of revision due to dislocation. It was based on 110 239 primary total hip replacements with a diagnosis of osteoarthritis collected by the Australian Orthopaedic Association National Joint Replacement Registry between September 1999 and D...

متن کامل

Association Between Total Hip Replacement Characteristics and 3-Year Prosthetic Survivorship: A Population-Based Study.

IMPORTANCE Total hip replacement (THR) is successful in treating hip arthritis. Prosthetic survivorship may depend on characteristics of the implant, notably THR fixation technique and bearing surface type. OBJECTIVE To compare THR short-term survivorship according to cement type and bearing surface. DESIGN, SETTING, AND PARTICIPANTS The cohort included all French patients aged 40 years or ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016