Self-gelatinizable copolymer immobilized glucose biosensor based on prussian blue modified graphite electrode.

نویسندگان

  • Q Deng
  • B Li
  • S Dong
چکیده

A novel poly(vinyl alcohol) grafting 4-vinylpyridine self-gelatinizable copolymer was adapted to immobilize glucose oxidase. The reduction of hydrogen peroxide (H2O2) was detected at a Prussian Blue (PB) modified graphite electrode. A stable and sensitive glucose amperometric biosensor is described. The copolymer is a good biocompatible polymer in which the glucose oxidase retains high activity. Moreover, the copolymer can adhere firmly to the inorganic PB membrane. The sensor showed an apparent Michaelis-Menten constant of 18 +/- 0.2 mM and a maximum current density of 1.14 microA cm-2 mM-1. The linear range is from 5 microM to 4.5 mM glucose and the detection limit is 0.5 microM glucose. The catalytic efficiency of PB for the reduction of H2O2 is higher than that for the oxidation of H2O2. Glucose concentrations in serum samples from healthy persons and diabetic patients were determined using the sensor. The results compared well with those provided by the hospital using a spectroscopy method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An amperometric glucose biosensor based on titania sol-gel/Prussian Blue composite film.

An improved amperometric glucose biosensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared by a vapor deposition method, on a Prussian Blue (PB)-modified electrode. The method combined the merits of immobilizing biomolecules in the titania sol-gel film by vapor deposition method and the synergic catalysis effects of PB and GOD molecules. Resul...

متن کامل

Prussian blue nanocubes decorated three-dimensional silver nanowires network for high-performance electrochemical biosensing

High sensitivity and selectivity play critical roles in practical applications of glucose biosensors. In this study, we reported a novel glucose biosensor based on three-dimensional (3D) structured biosensing film, which consisted of silver nanowires (AgNWs) network and Prussian blue nanocubes (PBNCs). 3D AgNWs network was successfully built on the electrode surface with assistance of self-asse...

متن کامل

Development of Amperometric Glucose Biosensor Based on Prussian Blue Functionlized TiO2 Nanotube Arrays

Amperometric biosensors consisting of oxidase and peroxidase have attracted great attention because of their wide application. The current work demonstrates a novel approach to construct an enzymatic biosensor based on TiO2 nanotube arrays (TiNTs) as a supporting electrode on which Prussian Blue (PB)-an "artificial enzyme peroxidase" and enzyme glucose oxidase (GOx) have been immobilized. For t...

متن کامل

Functionalized single-walled carbon nanotubes/polypyrrole composites for amperometric glucose biosensors

This article reports an amperometric glucose biosensor based on a new type of nanocomposite of polypyrrole (PPY) with p-phenyl sulfonate-functionalized single-walled carbon nanotubes (SWCNTs-PhSO3-). An environmentally friendly functionalization procedure of the SWCNTs in the presence of substituted aniline and an oxidative species was adopted. The nanocomposite-modified electrode exhibited exc...

متن کامل

Design and Fabrication of Biosensor Based on Immobilized AchE on Modified Electrode by Graphene-multiwall Carbon Nanotubs/Beta Cyclodexterin-chitosan

Organophosphorus (OP) forms an important class of toxic compounds. They inhibit acetyl cholinesterase (AChE, EC 3.1.1.7) that results in respiratory and myocardial malfunctions. Pesticides could be accumulated in vegetables and fruits, so detection of them is very important. The goals of this study are decreasing detection time and detection limit of methyl parathion bioprobe. In this research ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 123 10  شماره 

صفحات  -

تاریخ انتشار 1998