How does ankle-foot orthosis stiffness affect gait in patients with lower limb salvage?

نویسندگان

  • Elizabeth Russell Esposito
  • Ryan V Blanck
  • Nicole G Harper
  • Joseph R Hsu
  • Jason M Wilken
چکیده

BACKGROUND Ankle-foot orthoses (AFOs) are commonly prescribed during rehabilitation after limb salvage. AFO stiffness is selected to help mitigate gait deficiencies. A new custom dynamic AFO, the Intrepid Dynamic Exoskeletal Orthosis (IDEO), is available to injured service members but prescription guidelines are limited. QUESTIONS/PURPOSES In this study we ask (1) does dynamic AFO stiffness affect gait parameters such as joint angles, moments, and powers; and (2) can a given dynamic AFO stiffness normalize gait mechanics to noninjured control subjects? METHODS Thirteen patients with lower limb salvage (ankle arthrodesis, neuropathy, foot/ankle reconstruction, etc) after major lower extremity trauma and 13 control subjects who had no lower extremity trauma and wore no orthosis underwent gait analysis at a standardized speed. Patients wore their custom IDEO with posterior struts of three different stiffnesses: nominal (clinically prescribed stiffness), compliant (20% less stiff), and stiff (20% stiffer). Joint angles, moments, powers, and ground reaction forces were compared across the varying stiffnesses of the orthoses tested and between the patient and control groups. RESULTS An increase in AFO compliance resulted in 20% to 26% less knee flexion relative to the nominal (p = 0.003) and stiff (p = 0.001) conditions, respectively. Ankle range of motion and power generation were, on average, 56% (p < 0.001) and 63% (p < 0.001), respectively, less than controls as a result of the relatively fixed ankle position. CONCLUSIONS Patients with limb salvage readily adapted to different dynamic AFO stiffnesses and demonstrated few biomechanical differences among conditions during walking. None of the stiffness conditions normalized gait to controls. CLINICAL RELEVANCE The general lack of differences across a 40% range of strut stiffness suggests that orthotists do not need to invest large amounts of time identifying optimal device stiffness for patients who use dynamic AFOs for low-impact activities such as walking. However, choosing a stiffer strut may more readily translate to higher-impact activities and offer less chance of mechanical failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of an Articulated Ankle Foot Orthosis with Plantarflexion Resistance on the Gait: a Case Series of 2 Patients with Hemiplegia

Ankle-foot orthoses (AFOs) have been described to have positive effects on the gait biomechanics in stroke patients. The plantarflexion resistance of an AFO is considered important for hemiplegic patients, but the evidence is still limited. The purpose of this case series was to design and evaluate the immediate effect of an articulated AFO on kinematics and kinetics of lower-limb joints in str...

متن کامل

Return to running and sports participation after limb salvage.

BACKGROUND The ability to return to running and sports participation after lower extremity limb salvage has not been well documented previously. Although the ability to ambulate without pain or assistive devices is generally a criteria for a good limb salvage outcome, many patients at our institution have expressed a desire to return to a more athletic lifestyle to include running and sports pa...

متن کامل

Non-velocity-related effects of a rigid double-stopped ankle-foot orthosis on gait and lower limb muscle activity of hemiparetic subjects with an equinovarus deformity.

BACKGROUND AND PURPOSE This study investigated the non-velocity-related effects of a 1-bar rigid ankle-foot orthosis on the gait of hemiparetic subjects, with particular emphasis on the muscle activity of the paretic lower limb. METHODS Twenty-one hemiparetic subjects who had been using an ankle-foot orthosis for equinovarus deformity for <1 week participated. Patients walked cued by a metron...

متن کامل

Patient-Adaptive Prosthetic and Orthotic Leg Systems

Two computer-controlled devices for leg rehabilitation are presented: 1) an external knee prosthesis for trans-femoral amputees; and 2) a force-controllable ankle-foot orthosis to assist individuals suffering from drop-foot, a gait pathology resulting from muscle weakness in ankle dorsiflexors. Here muscle-like actuators and biologically-inspired control schemes are employed to enhance patient ...

متن کامل

The effect of ankle foot orthosis stiffness on the energy cost of walking: a simulation study.

BACKGROUND In stroke and multiple sclerosis patients, gait is frequently hampered by a reduced ability to push-off with the ankle caused by weakness of the plantar-flexor muscles. To enhance ankle push-off and to decrease the high energy cost of walking, spring-like carbon-composite Ankle Foot Orthoses are frequently prescribed. However, it is unknown what Ankle Foot Orthoses stiffness should b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 472 10  شماره 

صفحات  -

تاریخ انتشار 2014