Assuring the accuracy of home glucose monitoring.

نویسندگان

  • William A Alto
  • Daniel Meyer
  • James Schneid
  • Paul Bryson
  • Jon Kindig
چکیده

BACKGROUND An estimated 2.5 million diabetic patients in the United States practice self-monitoring of blood glucose (SMBG). The validity of the glucose values they obtain is in doubt. An American Diabetes Association consensus panel reported that up to 50% of SMBG determinations might vary more than 20% from their true value. Accurate glucose values are an integral part of intensive treatment and reduction of long-term complications. The objective of this study was to determine the technical skill and accuracy of SMBG in an outpatient population. METHODS This study was conducted in two family practice residency sites where 111 patients with type 1 and type 2 adult diabetes were observed testing their blood glucose values on their own glucose monitors. Patient-measured glucose levels were immediately compared with a laboratory value obtained from a calibrated hand-held glucose monitor. RESULTS Fifty-three percent of patient glucose values were within 10% of the control value, 84% were within 20% of the control value, and 16% varied 20% or more from the control value. Two patients had dangerously inaccurate glucose determinations. Four glucose monitors required replacement. The patients were observed using a 13-point checklist of critical steps in calibration and operation of their glucose monitor. Only 1 patient made no errors in testing. CONCLUSIONS Despite multiple technical errors when using SMBG, most patients obtained clinically useful values. This project can be easily introduced into a medical office.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors.Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed ...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

Continuous glucose monitoring accuracy results vary between assessment at home and assessment at the clinical research center.

BACKGROUND Continuous glucose monitoring system (CGMS) accuracy is of critical importance both in delivering therapeutic value and as a component of a closed-loop system. This study aims at assessing the differences between accuracy assessments of CGMS at home and at the clinical research center (CRC). METHODS Twelve patients with type 1 diabetes used the Dexcom® SEVEN® PLUS (DexCom, Inc.) CG...

متن کامل

Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, ho...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the American Board of Family Practice

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2002