How successful are small-diameter implants? A literature review.
نویسندگان
چکیده
BACKGROUND Edentulism is an important issue and will remain so due to high numbers of edentate individuals worldwide. For many years, complete dentures have been the only treatment option for this population. Implant overdentures have been shown to have many advantages over conventional complete dentures. However, although dissatisfied with their mandibular dentures, some edentate elders are reluctant to undergo even simple implant treatment due to factors such as cost and fear of surgery. To address these obstacles, this paper reports on a review of small-diameter implant (SDI) studies that were performed in the last two decades. The aim of this study is to (i) determine the survival of narrow diameter implants, (ii) determine whether survival is dependent on whether these implants are placed using a flap or flapless approach, and (ii) determine whether there is a relationship between length and implant survival in SDIs. METHODS In this review, studies were included that (i) involve implants with 3.5 mm diameter or less, (ii) have a randomized clinical trial, retrospective or prospective cohort design with human subjects, (iii) provide a follow up duration of at least 5 months following implant placement, (iv) include data on the survival rate of the implants. RESULTS Forty one studies meeting the above criteria were published between 1993 and 2011 using SDIs from a variety of companies and surface characteristics with diameters of 1.8 mm to 3.5 mm and lengths of 8 mm to 18 mm. A total of 10,093 SDIs were inserted in approximately 2762 patients. Twenty-six studies involved flap reflection techniques for implant placement, six studies used a flapless technique and two studies used both techniques; in the remaining studies, the technique was not specified. Follow up duration varied from 5 months to over 9 years. The survival rate reported in all screened studies was over 90%, including eight studies in which a 100% survival rate was reported. In 22 studies, the reported survival rate ranged from 95% to 99.9%. Failure was reported most often in short SDIs (less than or equal 13 mm) (n = 88) compared to longer ones (more than 13 mm). CONCLUSION Survival rates reported for SDI are similar to those reported for standard width implants. These survival rates did not appear to differ between studies that used flapless and flap reflection techniques. The failure rate appeared to be higher in shorter SDIs than in longer ones in the studies in which the length of the failed implants was reported. SDIs could be considered for use with fixed restorations and mandibular overdentures, since their success rate appears to be comparable to that of regular diameter implants. They might also be an efficient, low-cost solution for elders who wish to reduce problems with denture instability.
منابع مشابه
Immediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملHow Porous Nanofibers Have Enhanced the Engineering of Advanced Materials: A Review
Nanofibers are one-dimensional nanomaterialswith a superfine diameter and many potential applicationsdue to their desirable characteristics such as small diameter,high surface area, high flexibility, high porosity, and specialmechanical properties. In the recent years, porous nanofibershave been the subject of considerable research works in awide range of app...
متن کاملMaintenance of Dental Implants: A Review
Objective: Successful bonding of a dental implant to bone, which was referred to as osseointegration by Branemark has been well documented. However, long-term prognosis of an implant depends on adequate maintenance and long-term care. An effective maintenance program is required to preserve the health of peri-implant tissues. Several techniques have been suggested for this purpose but it is n...
متن کاملNarrow-diameter implants: Are they a predictable treatment option? A literature review
OBJECTIVE To evaluate the predictability of narrow-diameter implants as a treatment option in routine clinical practice. A literature review was performed of studies reporting clinical results obtained with these implants. Survival rates, peri-implant bone loss and related complications were evaluated. The working hypothesis was that narrow-diameter implants offer clinical results similar to th...
متن کاملA Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants
Dental implants made from binary titanium-zirconium (TiZr) alloys have shown promise as a high strength, yet biocompatible alternative to pure titanium, particularly for applications requiring small diameter implants. The aim of this review is to summarize existing literature reporting on the use of binary TiZr alloys for endosseous dental implant applications as tested in vitro, in animals and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 23 5 شماره
صفحات -
تاریخ انتشار 2012