Mechanical properties of human pericardium. Differences in viscoelastic response when compared with canine pericardium.
نویسندگان
چکیده
Whereas most experiments on the mechanical function of the pericardium have been performed on dogs, very little is known about the applicability of those data to humans. To examine the tensile viscoelastic properties of fresh human pericardium, we have used the methods from our previous study of canine pericardium. Although the mechanical responses of canine and human pericardium were qualitatively similar, human pericardium displayed a significantly greater viscous character. Human pericardium was 7.3 times thicker than canine pericardium, but was more extensible in stress-strain tests, with lower stiffness at a given strain. The static (elastic) stiffness of human pericardium seems identical to that of canine pericardium; lower stiffness per unit thickness of the human tissue at predicted physiological stresses was almost exactly compensated by the greater wall thickness. This effect was also seen in data on fracture strength and stiffness. However, human pericardium displayed greater viscous responses than the canine tissue. This was seen in doubled cyclic hysteresis losses, and greater stress relaxation and creep. Our results suggest that experiments on the viscoelastic properties of canine pericardium may not be directly applicable to humans, especially where dynamic mechanical properties are most important: i.e., in studies of ventricular function and the time-course of pericardial effusions.
منابع مشابه
Mechanical and structural correlates of canine pericardium.
We have assessed viscoelastic properties of pericardium within the physiological range of stresses and related mechanical behavior to fiber direction as defined by scanning electron microscopy. Stiffness, stress relaxation, and creep were measured in samples taken from the anterior surface of 14 canine pericardia. Stress-strain relations generally were not exponential; stiffness at a stress of ...
متن کاملTissue mechanics of canine pericardium in different test environments. Evidence for time-dependent accommodation, absence of plasticity, and new roles for collagen and elastin.
We have tested the mechanical properties of isolated canine pericardium at 37°C in Hanks' solution, and compared those results with similar tests on tissue at room temperature, both in Hanks' solution and merely kept moist with saline. Pericardium, which is nearly isotropic due to the layers of collagen aligned in different directions, is a composite material made up of collagen and elastin fib...
متن کاملComparison between the decellularized bovine pericardium and the conventional bovine pericardium used in the manufacture of cardiac bioprostheses
Introduction: In this paper, our objective was to compare the decellularized and conventional pericardium mechanical resistance and also its capability of inducing inflammatory response in an animal experimental model. Methods: In order to study these properties, we divided the pericardia into two groups: Group I pericardium conventionally treated with GTA and Group II – pericardium previously ...
متن کاملAge Dependent Differences in Collagen Alignment of Glutaraldehyde Fixed Bovine Pericardium
Bovine pericardium is used for heart valve leaflet replacement where the strength and thinness are critical properties. Pericardium from neonatal animals (4-7 days old) is advantageously thinner and is considered as an alternative to that from adult animals. Here, the structures of adult and neonatal bovine pericardium tissues fixed with glutaraldehyde are characterized by synchrotron-based sma...
متن کاملMechanical interactions between four heart chambers with and without the pericardium in canine hearts.
By using excised postmortem hearts obtained from 15 mongrel dogs with the pericardium intact, we investigated mechanical interactions between the four heart chambers from the standpoint of ventricular pressure-volume relationships. The interactions investigated were those between (1) the atrium and the ventricle, (2) the right ventricle and left ventricles, (3) the atrium and one ventricle vs. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 57 3 شماره
صفحات -
تاریخ انتشار 1985