Evolving compartment syndrome detected by loss of somatosensory- and motor-evoked potential signals during cervical spine surgery.

نویسندگان

  • Wesley H Bronson
  • David Forsh
  • Sheeraz A Qureshi
  • Stacie G Deiner
  • Donald J Weisz
  • Andrew C Hecht
چکیده

Neurologic injury is a rare but devastating complication of spinal surgery that can result in mild sensory to severe motor deficits. Surgeons increasingly use electrophysiological spinal cord function monitoring, including somatosensory- and motor-evoked potentials, intraoperatively to provide information about spinal cord function, aid in surgical decision making, improve outcomes, and reduce complication rates. By providing real-time information about the dorsal and anterior motor column function, somatosensory- and motor-evoked potentials signals allow surgeons to reverse noticeable changes and avoid devastating neurologic injuries. Recognizing changes in baseline signals in the setting of known risk factors enables surgeons to correct these risks. This article describes a case in which somatosensory- and motor-evoked potentials monitoring were lost in the setting of an impending right forearm compartment syndrome during 2-level anterior cervical diskectomy and fusion. To the authors' knowledge, this is the first reported case of spinal cord monitoring detecting an evolving compartment syndrome during cervical spine surgery. The early changes in signal intensity enabled the surgeon to search for a cause and remedy the situation by removing the infiltrated intravenous line. Without the observed changes in somatosensory- and motor-evoked potentials, it is likely that the compartment syndrome may have progressed to the point of requiring fasciotomy to prevent lasting neuromuscular injury. This article describes a new cause of changes in electrophysiological monitoring and further displays the usefulness of somatosensory- and motor-evoked potentials monitoring during even routine spinal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery.

BACKGROUND There has been little enthusiasm for somatosensory evoked potential monitoring in cervical spine surgery as a result, in part, of the increased risk of motor tract injury at this level, to which somatosensory monitoring may be insensitive. Transcranial electric motor evoked potential monitoring allows assessment of the motor tracts; therefore, we compared transcranial electric motor ...

متن کامل

Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion.

BACKGROUND CONTEXT Somatosensory evoked potentials (SSEPs) monitor global spinal cord function, and the interpretation of motor loss is based on inferred rather than direct measurements. Therefore, SSEPs may not be useful for identifying motor function deficits caused by anterior spinal column injury or nerve root injury during decompression or placement of instrumentation. For these reasons, a...

متن کامل

Bilateral C5 Palsy Following a Circumferential Surgery for Cervical Spondylotic Myelopathy: Case Report and Review (In press)

Background and Importance: The development of C5 root palsy is a well-known potential complication of cervical spine surgeries for the correction of cervical spondylotic myelopathy. It typically occurs unilaterally but on extremely rare occasions it might occur as a bilateral anomaly. The value of intraoperative neurophysiologic monitoring in detection of iatrogenic acute versus delayed onset C...

متن کامل

Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients--a review of 1,039 cases.

BACKGROUND CONTEXT Intraoperative somatosensory evoked potential (SSEP) monitoring has been shown to reduce the incidence of new postoperative neurological deficits in scoliosis surgery. However, its usefulness during cervical spine surgery remains a subject of debate. PURPOSE To determine the utility of intraoperative SSEP monitoring in a specific patient population (those with cervical radi...

متن کامل

Detection of evolving injury to the brachial plexus during transaxillary robotic thyroidectomy.

OBJECTIVES/HYPOTHESIS Continuous intraoperative neuromonitoring (IONM) of transcranial electric motor evoked potentials (tceMEPs) and somatosensory evoked potentials (SSEPs) has gained universal acceptance as an efficacious method for detecting emerging positional brachial plexopathy or peripheral nerve compression during spinal and shoulder surgery. This has implications for transaxillary thyr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 2012