Talbot interferometry with curved quasi-periodic gratings: towards large field of view X-ray phase-contrast imaging.

نویسندگان

  • Yangyang Sun
  • Wenxiang Cong
  • Yan Xi
  • Ge Wang
  • Shuo Pang
چکیده

X-ray phase-contrast imaging based on grating interferometry has become a common method due to its superior contrast in biological soft tissue imaging. The high sensitivity relies on the high-aspect ratio structures of the planar gratings, which prohibit the large field of view applications with a diverging X-ray source. Curved gratings allow a high X-ray flux for a wider angular range, but the interference fringes are only visible within ~10° range due to the geometrical mismatch with the commonly used flat array detectors. In this paper, we propose a design using a curved quasi-periodic grating for large field of view imaging with a flat detector array. Our scheme is numerically verified in the X-ray regime and experimentally verified in the visible optical regime. The interference fringe pattern is observed over 25°, with less than 10% of decrease in visibility in our experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

X-ray phase-contrast imaging at 100 keV on a conventional source

X-ray grating interferometry is a promising imaging technique sensitive to attenuation, refraction and scattering of the radiation. Applications of this technique in the energy range between 80 and 150 keV pose severe technical challenges, and are still mostly unexplored. Phase-contrast X-ray imaging at such high energies is of relevant scientific and industrial interest, in particular for the ...

متن کامل

Enhancing Tabletop X-Ray Phase Contrast Imaging with Nano-Fabrication

X-ray phase-contrast imaging is a promising approach for improving soft-tissue contrast and lowering radiation dose in biomedical applications. While current tabletop imaging systems adapt to common x-ray tubes and large-area detectors by employing absorptive elements such as absorption gratings or monolithic crystals to filter the beam, we developed nanometric phase gratings which enable table...

متن کامل

Phase Imaging with an X-ray Talbot Interferometer

X-ray Talbot interferometry (XTI) is described as a novel phase-sensitive X-ray imaging method. XTI uses two transmission gratings, and therefore in principle it functions with cone-beam X-rays of a broad energy band width, allowing its instrumentation with a compact X-ray source. Because an amplitude transmission grating is needed, X-ray lithography and electrochemical gold plating were employ...

متن کامل

Tilted-grating approach for scanning-mode X-ray phase contrast imaging.

Among the existent X-ray phase-contrast modalities, grating interferometry appears as a very promising technique for commercial applications, since it is compatible with conventional X-ray tubes and is robust from a mechanical point of view. However, since applications such as medical imaging and homeland security demand covering a considerable field of view, the fabrication of large-area grati...

متن کامل

Realization of optical carpets in the Talbot and Talbot-Lau configurations.

Talbot and Talbot-Lau effects are frequently used in lensless imaging applications with light, ultrasound, x-rays, atoms and molecules--generally in situations where refractive optical elements are non-existent or not suitable. We here show an experimental visualization of the intriguing wave patterns that are associated with near-field interferometry behind a single periodic diffraction gratin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 23 20  شماره 

صفحات  -

تاریخ انتشار 2015