Effect of directed training on reader performance for CT colonography: multicenter study.
ثبت نشده
چکیده
PURPOSE To define the interpretative performance of radiologists experienced in computed tomographic (CT) colonography and to compare it with that of novice observers who had undergone directed training, with colonoscopy as the reference standard. MATERIALS AND METHODS Physicians at each participating center received ethical committee approval and followed the committees' requests regarding informed consent. Nine experienced radiologists, nine trained radiologists, and 10 trained technologists from nine centers read 40 CT colonographic studies selected from a data set of 51 studies and modeled to simulate a population with positive fecal occult blood test results: Studies were obtained in eight patients with cancer, 12 patients with large polyp, four patients with medium polyp, and 27 patients without colonic lesions. Findings were verified with colonoscopy. An experienced radiologist used 50 endoscopically validated studies to train novice observers before they were allowed to participate. Observers used one software platform to read studies over 2 days. Responses were collated and compared with the known diagnostic category for each subject. The number of correctly classified subjects was determined for each observer, and differences between groups were examined with bootstrap analysis. RESULTS Overall, 28 observers read 1084 studies and detected 121 cancers, 134 large polyps, and 33 medium polyps; 448 healthy subjects were categorized correctly. Experienced radiologists detected 116 lesions; trained radiologists and technologists detected 85 and 87 lesions, respectively. Overall accuracy of experienced observers (74.2%) was significantly better than that of trained radiologists (66.6%) and technologists (63.2%). There was no significant difference (P=.33) between overall accuracy of trained radiologists and that of technologists; however, some trainees reached the mean performance achieved by experienced observers. CONCLUSION Experienced observers interpreted CT colonographic images significantly better than did novices trained with 50 studies. On average, no difference between trained radiologists and trained technologists was found; however, individual performance was variable and some trainees outperformed some experienced observers.
منابع مشابه
Fundamental Elements for Successful Performance of CT Colonography (Virtual Colonoscopy)
There are many factors affecting the successful performance of CT colonography (CTC). Adequate colonic cleansing and distention, the optimal CT technique and interpretation with using the newest CTC software by a trained reader will help ensure high accuracy for lesion detection. Fecal and fluid tagging may improve the diagnostic accuracy and allow for reduced bowel preparation. Automated carbo...
متن کاملCT colonography standards.
Computed tomography (CT) colonography is the established successor to the barium enema for the detection of colonic neoplasia due to superior performance and patient experience. Consequently, CT colonography is widely disseminated across Western populations and increasingly provided by both subspecialist and general radiologists alike. As a result, CT colonography is now part of the core traini...
متن کاملA CAD Utilizing 3D Massive-Training ANNs for Detection of Flat Lesions in CT Colonography: Preliminary Results
Our purpose was to develop a computer-aided diagnostic (CAD) scheme for detection of flat lesions (also known as superficial elevated or depressed lesions) in CT colonography (CTC), which utilized 3D massive-training artificial neural networks (MTANNs) for false-positive (FP) reduction. Our CAD scheme consisted of colon segmentation, polyp candidate detection, linear discriminant analysis, and ...
متن کاملComparison of the diagnostic performance of CT colonography interpreted by radiologists and radiographers
OBJECTIVE To compare computed tomographic colonography (CTC) performance of four trained radiographers with the CTC performance of two experienced radiologists. METHODS Four radiographers and two radiologists interpreted 87 cases with 40 polyps ≥6 mm. Sensitivity, specificity, and positive predictive value (PPV) were assessed on a per-patient basis. On a per-polyp basis, sensitivity was calcu...
متن کاملCT colonography with teleradiology: effect of lossy wavelet compression on polyp detection--initial observations.
PURPOSE To assess the consequences of lossy compression on the diagnostic accuracy of CT colonography for detecting colonic polyps. MATERIALS AND METHODS Helical CT images of cleansed colonic segments were evaluated. Source images were compressed to 1:1, 10:1, and 20:1 ratios with lossy wavelet compression. Two independent readers blinded to corresponding colonoscopic results analyzed 144 ran...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 242 1 شماره
صفحات -
تاریخ انتشار 2007