Sound Localization and Interaural Time Sensitivity with Bilateral Cochlear Implants

نویسنده

  • Becky Bikkei Poon
چکیده

Bilateral cochlear implantation is becoming more common as clinicians attempt to provide better sound-source localization and speech reception in noise for cochlear implant (CI) users. While some improvement over the abilities of monolateral implantees has been documented, bilateral performance for CI users is far from that achieved with normal hearing. Identifying factors that limit bilateral performance has been difficult because little is understood about CI listeners' localization abilities, their sensitivity to interaural cues, and the relationships between them. To better understand bilateral electric hearing, five bilateral CI users' abilities to locate sound sources and their sensitivities to interaural time difference (ITD) were studied in this thesis. Unlike past studies, monolateral and bilateral performance was recorded before and after exposure to daily, bilateral-CI listening using constantand roving-level stimuli. For constant-level stimuli, increasing bilateral-listening experience improved all subjects' bilateral performance but degraded two subjects' monolateral performance. Using roving-level stimuli, increasing bilateral-listening experience also improved bilateral performance but did not alter monolateral performance. Our results show that depending on the method of evaluation, the benefit of bilateral CIs over monolateral CI could be overstated for some subjects. A simple decision model was used to predict subjects' localization performance based on their sensitivity to interaural time and level differences (TD and ILD) measured through their sound processors. The predicted performance indicated that the measured performance could be accounted for by subjects' ILD sensitivity but not by their ITD sensitivity alone. Poor ITD sensitivity may be one reason that bilateral CI users' localization performance is poor compared to that of normal-hearing (NH) listeners. To improve ITD sensitivity, a first step is to characterize TD sensitivity on single, interaural electrode pairs because data in the literature is incomplete. In particular, the dependence of ITD sensitivity on the repetition rate and the number of pulses in the unmodulated pulse trains was studied. Just noticeable difference (JND) of ITD was measured with four subjects on their most ITD-sensitive, interaural electrode pair. At low rate (50 pps), ITD JND improved with increasing number of pulses, indicating integration of ongoing ITD cues. The best ITD JNDs were 85 354 pts. Using 800-pps

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perception of Binaural Cues Develops in Children Who Are Deaf through Bilateral Cochlear Implantation

There are significant challenges to restoring binaural hearing to children who have been deaf from an early age. The uncoordinated and poor temporal information available from cochlear implants distorts perception of interaural timing differences normally important for sound localization and listening in noise. Moreover, binaural development can be compromised by bilateral and unilateral audito...

متن کامل

Localization in Reverberation with Cochlear Implants Predicting Performance from Basic Psychophysical Measures

Users of bilateral cochlear implants (CIs) experience difficulties localizing sounds in reverberant rooms, even in rooms where normal-hearing listeners would hardly notice the reverberation. We measured the localization ability of seven bilateral CI users listening with their own devices in anechoic space and in a simulated reverberant room. To determine factors affecting performance in reverbe...

متن کامل

Sensitivity to interaural time differences in the inferior colliculus with bilateral cochlear implants.

Bilateral cochlear implantation attempts to increase performance over a monaural prosthesis by harnessing the binaural processing of the auditory system. Although many bilaterally implanted human subjects discriminate interaural time differences (ITDs), a major cue for sound localization and signal detection in noise, their performance is typically poorer than that of normal-hearing listeners. ...

متن کامل

The use of interaural time and level difference cues by bilateral cochlear implant users.

While considerable evidence suggests that bilateral cochlear implant (CI) users' sound localization abilities rely primarily on interaural level difference (ILD) cues, and only secondarily, if at all, on interaural time difference (ITD) cues, this evidence has largely been indirect. This study used head-related transfer functions (HRTFs) to independently manipulate ITD and ILD cues and directly...

متن کامل

Binaural jitter improves interaural time-difference sensitivity of cochlear implantees at high pulse rates.

Interaural time difference (ITD) arises whenever a sound outside of the median plane arrives at the two ears. There is evidence that ITD in the rapidly varying fine structure of a sound is most important for sound localization and for understanding speech in noise. Cochlear implants (CIs), neural prosthetic devices that restore hearing in the profoundly deaf, are increasingly implanted to both ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007