High-energy and thermal-neutron imaging and modeling with an amorphous silicon flat-panel detector.

نویسندگان

  • Thomas N Claytor
  • Terry N Taddeucci
  • Charles R Hills
  • Deborah A Summa
  • Anthony W Davis
  • Thomas E McDonald
  • Mark J Schwab
چکیده

The Los Alamos Neutron Science Center (LANSCE) operates two spallation neutron sources dedicated to research in materials science, condensed-matter physics, and fundamental and applied nuclear physics. Prior to 1995, all thermal neutron radiography at Los Alamos was done on a beam port attached to the Omega West reactor, a small 8MW research reactor used primarily for radioisotope production and prompt and delayed neutron activation analysis. After the closure of this facility, two largely independent radiography development efforts were begun at LANSCE using moderated cold and thermal neutrons from the Target-1 source and high-energy neutrons from the Target-4 source. Investigations with cold and thermal neutrons employed a neutron converter and film, a scintillation screen and CCD camera system, and a new high-resolution amorphous silicon (a-Si) flat-panel detector system. Recent work with high-energy neutrons (En > 1 MeV) has involved storage-phosphor image plates. Some comparison high-energy images were obtained with both image plates and the a-Si panel and showed equivalent image quality for approximately equal exposure times.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

Simulation of a Neutron Detector for Real Time Imaging Applications

Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...

متن کامل

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems.

OBJECTIVE The aim of this study was to compare the image quality and radiation dose in chest imaging using an amorphous silicon flat-panel detector system and an amorphous selenium flat-panel detector system. In addition, the low-contrast performance of both systems with standard and low radiation doses was compared. MATERIALS AND METHODS In two groups of 100 patients each, digital chest radi...

متن کامل

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1 Comparison of Amorphous Selenium and Amorphous Silicon Flat-Panel Detectors

Digital radiographic flat-panel detectors may operate with direct or indirect manners of converting x-ray photon energy into spatial energy signals. Advances in both technologies have led to radiographic work areas that are faster and lend toward lower patient radiation doses. Superior image quality with an abundance of post-processing capabilities is a benefit as well. Whether based on amorpho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2004