Measurement of carbon monoxide transfer and lung volume in ventilated subjects.

نویسندگان

  • P D Macnaughton
  • C J Morgan
  • D M Denison
  • T W Evans
چکیده

A simple method for measuring lung volume and carbon monoxide transfer factor (TLCO) by a rebreathing technique was assessed in nine healthy volunteers undergoing intermittent positive pressure ventilation (IPPV). Measurements of TLCO, alveolar volume (VA) and carbon monoxide transfer coefficient (KCO) made at three inspired oxygen concentrations (21, 35 and 70%) during IPPV were compared to those obtained during spontaneous breathing. The effects of 10 cmH2O positive end expiratory pressure (PEEP) were also studied. Pulmonary capillary blood volume (Vc) and the diffusing capacity of the alveolar capillary membrane (Dm) were derived. There was a close correlation between measurements of TLCO during IPPV (TLCOIPPV) and spontaneous breathing (TLCOSV) (r = 0.92). Ventilated TLCO was 64 +/- 8% of spontaneously breathing TLCO. There was a close agreement between ventilated and spontaneously breathing measurements of KCO (r = 0.95; mean difference 0.14, 95% limits of agreement +0.37 to -0.09 mmol.min-1 x kPa-1 x l-1). Vc was 92 +/- 23 ml during spontaneous breathing and 72 +/- 21 ml during IPPV (p < 0.05). PEEP of 10 cmH2O significantly increased functional residual capacity (2.3 +/- 0.5 to 3.5 +/- 0.6 l) and decreased TLCO (5.9 +/- 1.0 to 5.3 +/- 1.2 mmol.min-1 x kPa-1), KCO (1.7 +/- 0.2 to 1.1 +/- 0.3 mmol.min-1 x kPa-1 x l-1) and Vc (82 +/- 22 to 56 +/- 20 ml). Dm did not change with PEEP. This simple method may be a useful means of assessing gas exchange and lung volume in ventilated subjects. It showed that PEEP increased lung volume but reduced TLCO and that this reduction appeared to be due to a reduction in capillary blood volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilatory function in the Eisenmenger syndrome.

Ventilatory function and carbon monoxide transfer factor were studied in nine adult patients with post-tricuspid intracardiac defects and the Eisenmenger syndrome. A consistent mild defect of ventilatory function was found, with raised residual volume and closing capacity and reduction of other lung volumes and maximal expiratory flows. Maximal expiratory flow was particularly reduced at low lu...

متن کامل

Pulmonary function in healthy young adult Indians in Madras.

Forced vital capacity, forced expiratory volume in one second, functional residual capacity, residual volume, total lung capacity, and single breath diffusing capacity measurements (effective alveolar volume, carbon monoxide transfer factor, and transfer coefficient) were measured in 247 young healthy adults (130 male, 117 female) aged 15-40 years living in Madras. Subjects were of Dravidian st...

متن کامل

Effect of pattern and severity of respiratory muscle weakness on carbon monoxide gas transfer and lung volumes.

In clinical practice, an elevated carbon monoxide (CO) transfer coefficient (KCO) and restrictive ventilatory defect are taken as features of respiratory muscle weakness (RMW). However, the authors hypothesised that both pattern and severity of RMW effect gas transfer and lung volumes. Measurements of CO transfer and lung volumes were performed in patients with isolated diaphragm weakness (n=10...

متن کامل

Large lungs and growth hormone: an increased alveolar number?

Previous physiological studies suggest that increased lung growth in patients with acromegaly is associated with either a normal or above normal pulmonary transfer factor. These findings can be interpreted to suggest either alveolar hypertrophy or hyperplasia as the mechanism for lung growth in this condition. Since the ventilated airspaces retain normal elastic properties, we wanted to determi...

متن کامل

Reduction of pulmonary capillary blood volume in patients with severe unexplained pulmonary hypertension.

BACKGROUND Unexplained or primary pulmonary hypertension results in an obliteration and obstruction of resistance pulmonary arteries. In these patients gas exchange is impaired and the measurement of gas transfer for carbon monoxide is usually reduced. This has been thought to represent a reduction in pulmonary alveolar capillary blood volume (Vc). A single breath test, measuring simultaneously...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 1993