Legionella species isolated from cooling towers in Kuala Lumpur.
نویسندگان
چکیده
Three building complexes in Kuala Lumpur were surveyed for the presence of legionellae in cooling towers. The organisms were grown from 12 out of 46 samples of water collected from 30 towers. L. pneumophila serogroups 1 and 7 were the commonest serogroups isolated. None belonged to the Pontiac subgroup of L. pneumophila serogroup 1.
منابع مشابه
An alkaline approach to treating cooling towers for control of Legionella pneumophila.
Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances...
متن کاملProtocol for sampling environmental sites for legionellae.
A protocol for sampling environmental sites was developed and used to identify possible sources of Legionella species in support of epidemiologic investigations at two hospitals. In hospital A, legionellae were isolated from 43 of 106 (40%) different sites. Three separate Legionella pneumophila serotypes and a previously unrecognized species were present in different combinations in the positiv...
متن کاملLegionella species and serogroups in Malaysian water cooling towers: identification by latex agglutination and PCR-DNA sequencing of isolates.
In this study, we investigated the distribution of Legionella species in water cooling towers located in different parts of Malaysia to obtain information that may inform public health policies for the prevention of legionellosis. A total of 20 water samples were collected from 11 cooling towers located in three different states in east, west and south Malaysia. The samples were concentrated by...
متن کاملFirst isolation of Legionella pneumophila in Sri Lanka.
OBJECTIVES To determine the presence of legionellae and species composition of the genus Legionella in Sri Lankan hotel cooling towers, and to determine the previous exposure of hotel workers to Legionella pneumophila. DESIGN Collection of water samples from 16 cooling towers of air conditioning plants from 7 representative hotels, and blood samples from hotel workers. SETTING Department of...
متن کاملOutbreak of legionnaires' disease from a cooling water system in a power station.
In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Medical journal of Malaysia
دوره 47 1 شماره
صفحات -
تاریخ انتشار 1992