Working paper developed for a NASA-sponsored study of solar cells Significance Part 6: Tutorials, textbooks and reviews Lightning interception by an unprotected building 30 feet high x 45 feet long on flat land, in the Cleveland area, can be estimated at one strike per 200 years on the average. However, peculiar configuration can easily affect this estimate upward or downward. Means are available to install air terminals so that interception will be done by these, without harm to the roof-mounted photovoltaic array. Economic trade-off on the decision to invest in a lightning protection system during the life of the development project must also include intangible factors such as schedule delays and postmortem apologies for insufficient protection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protection of Floating Roof Petroleum Storage Tanks against Lightning Strokes

The subject of petroleum storage tank fires has gained a great deal of attention due to the high cost of petroleum, and the consequent disruption of petroleum production; therefore, much of the current research has focused on petroleum storage tank fires. Also, the number of petroleum tank fires is oscillating between 15 and 20 fires per year. About 33% of all tank fires are attributed to light...

متن کامل

Lightning Protection of Ehv Substations in Iran

Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.

متن کامل

Roof Integrated Solar Absorbers: The Measured Performance of “Invisible” Solar Collectors: Preprint

The Florida Solar Energy Center (FSEC), with the support of the National Renewable Energy Laboratory (NREL), has investigated the thermal performance of solar absorbers which are an integral yet indistinguishable part of a building’s roof. The first roof-integrated solar absorber (RISA) system was retrofitted into FSEC’S Flexible Roof Facility in Cocoa, Florida in September 1998. This “proof-of...

متن کامل

Multi Objective Optimization on Insulated Residential Roof with Solar Water Heating System Using Grey Relation Analysis (RESEARCH NOTE)

In this work, a multi-objective optimization on novel insulated roof with solar water heating system at low material cost has been carried out through Taguchi based grey relational analysis technique. The novel roofs have concrete, insulating polyurethane, and a channel of water in a metallic pipe tunneling the chromium block. Chromium block is used to conduct more heat to raise the water to re...

متن کامل

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004