A 3 T sodium and proton composite array breast coil.

نویسندگان

  • Joshua D Kaggie
  • J Rock Hadley
  • James Badal
  • John R Campbell
  • Daniel J Park
  • Dennis L Parker
  • Glen Morrell
  • Rexford D Newbould
  • Ali F Wood
  • Neal K Bangerter
چکیده

PURPOSE The objective of this study was to determine whether a sodium phased array would improve sodium breast MRI at 3 T. The secondary objective was to create acceptable proton images with the sodium phased array in place. METHODS A novel composite array for combined proton/sodium 3 T breast MRI is compared with a coil with a single proton and sodium channel. The composite array consists of a 7-channel sodium receive array, a larger sodium transmit coil, and a 4-channel proton transceive array. The new composite array design utilizes smaller sodium receive loops than typically used in sodium imaging, uses novel decoupling methods between the receive loops and transmit loops, and uses a novel multichannel proton transceive coil. The proton transceive coil reduces coupling between proton and sodium elements by intersecting the constituent loops to reduce their mutual inductance. The coil used for comparison consists of a concentric sodium and proton loop with passive decoupling traps. RESULTS The composite array coil demonstrates a 2-5× improvement in signal-to-noise ratio for sodium imaging and similar signal-to-noise ratio for proton imaging when compared with a simple single-loop dual resonant design. CONCLUSION The improved signal-to-noise ratio of the composite array gives breast sodium images of unprecedented quality in reasonable scan times.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Nested Dual Frequency Birdcage/Stripline Coil for Sodium/Proton Brain Imaging at 7T

Introduction: Dual tuned sodium/proton coils are valuable for multi-nuclear magnetic resonance imaging and spectroscopy. Due to low sodium content in the body and its low gyromagnetic ratio, the critical design aim for a sodium/proton coil is to maximize sodium sensitivity and homogeneity while maintaining adequate proton sensitivity. This has previously been achieved using a dual-tuned birdcag...

متن کامل

Trap Design Performance for RF Coils for Dual-frequency MRI & MRS

Introduction The growing availability of high-field whole body scanners has generated increasing interest in non-proton in vivo spectroscopy, and with it, multinuclear RF coil design. In most non-proton applications, simultaneous or sequential operation at the proton frequency is required as well; proton decoupling, scout imaging, and polarization transfer methods are cases where transmission/r...

متن کامل

MR Spectroscopic Imaging of Peripheral Zone in Prostate Cancer Using a 3T MRI Scanner: Endorectal versus External Phased Array Coils

Magnetic resonance spectroscopic imaging (MRSI) detects alterations in major prostate metabolites, such as citrate (Cit), creatine (Cr), and choline (Ch). We evaluated the sensitivity and accuracy of three-dimensional MRSI of prostate using an endorectal compared to an external phased array "receive" coil on a 3T MRI scanner. Eighteen patients with prostate cancer (PCa) who underwent endorectal...

متن کامل

Sodium MR imaging of kidney and other abdominal organs using a dual-tuned body RF coil at 7T

[Introduction] In vivo sodium MR imaging is promising because it is capable of providing physiologic and metabolic tissue information beyond conventional proton MR imaging. Unfortunately, the image quality of sodium MR imaging is poor when compared with proton imaging because of the low SNR due to the inherent low biological sodium content and low MR sensitivity. The low SNR problem may be alle...

متن کامل

Assessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX

Background: The present study aimed to investigate the equivalent dose in vital organs, including heart and lung, due to secondary particles produced during breast proton therapy. Materials and Methods: The numerical ORNL female-phantom was improved and simulated using the Monte Carlo MCNPX code. The depth-dose profile of proton beams with different energies was simulated. The proper energy ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2014