Retinal oximetry using ultrahigh-resolution optical coherence tomography
نویسندگان
چکیده
BACKGROUND The purpose of this study was to investigate the repeatability of retinal oximetry using slit-lamp adapted ultrahigh-resolution optical coherence tomography (SL-UHR-OCT). METHODS SL-UHR-OCT was developed and fringe patterns were obtained for a major retinal artery and a major retinal vein. A-scans at the central wavelengths of 805 nm and 855 nm were analyzed for calculating optical density ratios (ODRs), from which the percentage oxygen saturation was calculated. Measurements were made on two occasions for each person. Repeatability and coefficients of repeatability were calculated. RESULTS The mean ODRs of the artery were 0.79 ± 0.86 and 0.88 ± 0.97 in sessions 1 and 2, respectively. The mean ODRs of the vein were -0.08 ± 0.69 and 0.14 ± 0.77 between the two sessions, and were significantly lower than that of the artery (P < 0.05). The coefficients of repeatability were 1.44 and 1.81 for the artery and vein, respectively. The mean oxygen saturation of the major retinal artery was 94% ± 45% and 98% ± 51% in sessions 1 and 2, respectively, and the mean oxygen saturation of the major retinal vein was 48% ± 36% and 60% ± 40% between sessions. CONCLUSION Optical coherence tomographic oximetry for evaluating retinal oxygen saturation was subject to variation, although the averaged measurements in repeated sessions were matched. Further work on reducing variation will be needed.
منابع مشابه
Intact retinal tissue and retinal pigment epithelium identified within a coloboma by high-speed, ultrahigh-resolution optical coherence tomography.
PURPOSE The purpose of this study was to report on a posterior segment coloboma manifesting unusual morphology as determined by high-speed, ultrahigh-resolution optical coherence tomography imaging. METHODS A 47-year-old woman with bilateral colobomas was evaluated by fundus examination and high-speed, ultrahigh-resolution optical coherence tomography imaging. RESULTS Imaging with high-spee...
متن کاملHistologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography.
PURPOSE To compare ultrahigh-resolution optical coherence tomography (OCT) cross-sectional images of the pig retina with histology, to evaluate the potential of ultrahigh-resolution OCT for enhanced visualization of intra- and subretinal structures. METHODS Ultrahigh-resolution OCT images were acquired with 1.4- micro m axial x 3- micro m transverse resolution from in vitro posterior eyecup p...
متن کاملUltrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization
Chromatic aberrations are an important design consideration in high resolution, high bandwidth, refractive imaging systems that use visible light. Here, we present a fiberbased spectral/Fourier domain, visible light OCT ophthalmoscope corrected for the average longitudinal chromatic aberration (LCA) of the human eye. Analysis of complex speckles from in vivo retinal images showed that achromati...
متن کاملThree-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.
PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...
متن کاملThree-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator
A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained wi...
متن کامل