The FSE Cusp Artifact: A Phase Wrap-In Artifact Seen on Routine Clinical MR Images of the Knee

نویسنده

  • Jae K. Kim
چکیده

In the course of routine fast spin echo (FSE) magnetic resonance (MR) imaging of knees, we have noticed a distinct and recurrent artifact on MR sagittal knee images. The artifact usually appears as a focal dot of high signal intensity and/or c-shaped ripples at a non-orthogonal angle (Figure 1). The technical features of this artifact have been previously described in an ISMRM abstract in 1995, when the artifact was termed the FSE “cusp” artifact [ 11. In the course of our investigation, we have found that the FSE cusp artifact has a high prevalence in clinical MR images of the knee and that it can occasionally obscure anatomic detail that is required for clinical evaluation and diagnosis. We have additionally noted a similar FSE artifact in the presence of metal implants (Figure 2). Despite its prevalence, however, the FSE cusp artifact is still not well known. In this abstract, we describe the origin, nature, clinical prevalence, and methods for management of the FSE cusp artifact when it is encountered clinically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of FSE Cusp Artifact Using Slice Tilting

Introduction With specific combinations of B0-field, B1-field, and gradient field, peripheral signals outside the prescribed field of view (FOV) can fold back onto the image, resulting in a bright spot, a series of spots, a band, or a “feather-like” artifact along the phase encoding direction. In a fast spin echo (FSE) image, this type of artifact has been termed as cusp artifact [1,2], annefac...

متن کامل

New MR imaging methods for metallic implants in the knee: artifact correction and clinical impact.

PURPOSE To evaluate two magnetic resonance imaging (MRI) techniques, slice encoding for metal artifact correction (SEMAC) and multiacquisition variable-resonance image combination (MAVRIC), for their ability to correct for artifacts in postoperative knees with metal. MATERIALS AND METHODS A total of 25 knees were imaged in this study. Fourteen total knee replacements (TKRs) in volunteers were...

متن کامل

High-resolution Small Field-of-view 3 Tesla Mri with 32-channel Head Coil by Appropriately Selected Coil Elements Reconstruction Method

BACKGROUND AND PURPOSE 3-T MRI has been introduced into clinical examinations and is widely used [1]. High-resolution imaging is often essential as a clinical study for the diagnosis of diseases that show only subtle changes in the brain [2]. Since the 32-channel phased-array head coil offers a superb signal-to-noise ratio (SNR), high-quality images can be obtained when used with a 3-T MRI scan...

متن کامل

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999