Effect of Temperature Variation on the Cytotoxicity of Cast Dental Alloys and Commercially Pure Titanium
نویسندگان
چکیده
UNLABELLED Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. MATERIAL AND METHODS Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37 degrees C and thermocycling (37 degrees C/5 degrees C/37 degrees C/55 degrees C/37 degrees C). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (alpha=0.05). RESULTS The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. CONCLUSION Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.
منابع مشابه
INVESTIGATION ON THE EFFECTS OF MAGNETIC FIELD ON BROMIDE-INDUCED PITTING OF COMMERCIALLY PURE TITANIUM
Abstract: In chloride salt solutions, titanium alloys exhibit reasonably high pitting potentials as high as +10 V (vs. Ag/AgCl) at room temperatures. On the other hand, anodic pitting potentials are significantly lower in bromide solutions. In this study, pitting corrosion of commercially pure titanium in aqueous NaBr solution of 0.1 M concentration at room temperature was studied and the e...
متن کاملNumerical and Experimental Investigation of the Effect of Open-Die Hot Deep Drawing Process Parameters on the Formability of Commercially Pure Titanium
In the present study, the finite element analysis of the hot deep drawing process of commercially pure (CP) titanium has been performed without the blank holder in order to investigate the influence of temperature (T), die radius (Rd) and blank diameter (D) on the maximum punch force (Fp) and minimum thickness of the blank (t). Tensile tests were first conducted to extract...
متن کاملVickers hardness of cast commercially pure titanium and Ti-6Al-4V alloy submitted to heat treatments.
The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat trea...
متن کاملThe influence of commercially pure titanium and titanium-aluminum-vanadium alloy on the final shade of low-fusing porcelain.
AIMS The aims of this study were to investigate the influence of commercially pure titanium (PTi) and titanium-aluminum-vanadium (Ti-6Al-4V) alloys (TiA) on the final shade of low-fusing porcelain bonded to them and to compare the shade changes with those of three conventional metal-ceramic systems. METHODS AND MATERIALS A titanium casting unit was used to cast PTi and Ti-6Al-4V alloy specime...
متن کاملCorrosion Analysis of an Experimental Noble Alloy on Commercially Pure Titanium Dental Implants
OBJECTIVE To determine whether the Noble Bond® Argen® alloy was electrochemically suitable for the manufacturing of prosthetic superstructures over commercially pure titanium (c.p. Ti) implants. Also, the electrolytic corrosion effects over three types of materials used on prosthetic suprastructures that were coupled with titanium implants were analysed: Noble Bond® (Argen® ), Argelite 76sf +® ...
متن کامل